Nexen SE 625 883000 User Manual
Page 5

5
FORM NO. L-20078-C-0210
INTRODUCTION
Nexen’s DAP is a combination air actuated clutch and
spring engaged brake. The unit’s brake remains engaged
until air is applied to engage the clutch. Because of the
internal construction of the DAP, overlap (simultaneous
engagement of both clutch and brake) is impossible.
Nexen’s DAP is suited for mounting on standard NEMA
"C" flange mounting faces such as reducer units and
outputs, and motor flanges. An “L” shaped foot is also
available for free standing applications.
MOUNTING ON MOTORS AND REDUCER OUTPUT
SHAFTS
1. Position motor or reducer output shaft upward and
insert Key (Item 31).
2. Rotate DAP keyway upward and slide unit approximately
1.5" [38.1 mm] onto the shaft.
3. Rotate entire unit to line up mounting holes in flanges.
INSTALLATION
MOUNTING ON REDUCER INPUT FLANGES
1. Position DAP output shaft upward and insert Key (Item
31) into keyway.
2. With keyway in reducer also pointing up, slide unit up
to reducer flange.
NOTE
Observe location of air inlet and orientate to suit mounting
requirements.
4. Push DAP all the way onto shaft until mounting flanges
are flush.
5. Install four Cap Screws (Item 26) and Lockwashers
(Item 20) and tighten securely.
FOOT MOUNTING
1. Cradle output flange onto Nexen’s “L” shaped foot.
2. Install four cap screws supplied with foot into output
flange.
NOTE
Observe location of air inlet and rotate unit to suit
installation.
3. Install cap screws supplied with reducer and tighten
until mounting faces are flush.
3. Mount DAP Clutch/Brake/Foot combination to machine
frame.
4. Install sheaves, sprockets, or couplings onto unit’s
output shaft as required.