FORM NO. L-20123-B-0210

Nexen Waterproof Guards allow existing Modules to be used in a wider range of applications. To install the Nexen Waterproof
Guard, remove existing Guard Ring Assembly and replace with Waterproof Guard. Align one of the four ribs of the housing
directly beneath clamp of Waterproof Guard. Tighten screws (Item 4) into attached cage nuts (Item 6) to 35 in-lbs of
torque. If piece parts are not connected to guard upon arrival, reassemble as shown below.

INSTALLATION

PARTS LIST

Item

Description

Qty

1

Guard

1

2

Rect. Washer

2

3

Vinyl Tape

2

4

Screw

2

5

Retaining Nut

2

6

Cage Nut

2

Model

Product Number

MDU-625/875

929501

MBU-625/875

929502

MDU-1125/1375

935901

MBU-1125/1375

935902