INSTALLATION

Refer to Figure 1.
1. Secure a sheave or sprocket onto the pilot end of the

clutch/brake (See bolt sizes in Table 1).

2. Insert the Key (Item 18) onto the machine shaft keyway.
3. Slide the LSCB onto the machine shaft.

4. Secure the clutch-brake to the machine shaft using the

three Set Screws (Item 16).

5. Attach the air supply line to the air chamber inlet port

and orient in the six o’clock position to avoid water from

accumulating inside the air chamber.

6. Attach an anti-rotation device to the clutch-brake using

one of the two, .250-20 tapped holes located 180°
apart in the air chamber (Item 3). The anti-rotation
device must be capable of absorbing the brake torque
and the design is the responsibility of the machine
designer (See Table 1).

Table 1

Model Size

LSCB-32HT LSCB-44

LSCB-54

Bolt Size

1/4 - 20

1/4 - 20

5/16 - 20

Figure 1

16

16

2

14

1/4-20, two
anti-rotation
fixing holes
180° apart

1/8 NPT air inlet,
orient in the
“six o’clock”
position

CAUTION

Model LSCB is a driven shaft mounted,
clutch-brake with a normally-on (spring
engaged), hub stop brake. This unit design
is not intended to mount on a motor shaft.

NOTE

Nexen pneumatically actuated devices require clean, pressure regulated air for maximum performance and life.

All seals in Nexen Pneumatically operated devices are lubricated for life and do not require additional lubrication.
However, some customers prefer to use an air line lubricator, which injects oil into the pressurized air, forcing an

oil mist into the air chamber. This is acceptable, but care must be taken to ensure once an air mist lubrication

system is used, it is continually used over the life of the product as the oil mist may wash free the factory

installed lubrication.
Locate the lubricator above and within ten feet of the product, and use low viscosity oil such as SAE-10.
Synthetic lubricants are not recommended.
Nexen product's bearings are shielded and pre-lubricated, and require no further lubrication.

LUBRICATOR DRIP RATE SETTINGS

1. Close and disconnect the air line from the unit.

2. Turn the Lubricator Adjustment Knob counterclockwise

three complete turns.

3. Open the air line.

LUBRICATION

CAUTION

These settings are for Nexen supplied

lubricators. If you are not using a Nexen

lubricator, calibration must follow the

manufacturer's suggested procedure.

4. Close the air line to the unit when a drop of oil forms

in the Lubricator Sight Gage.

5. Connect the air line to the unit.

6. Turn the Lubricator Adjustment Knob clockwise until

closed.

7. Turn the Lubricator Adjustment Knob counterclockwise

one-third turn.

8. Open the air line to the unit.