Nexen LSCB-32 923522 User Manual
Page 5
FORM NO. L-21143-J-0413
5
INSTALLATION
Refer to Figure 1.
1. Secure a sheave or sprocket onto the pilot end of the
clutch/brake (See bolt sizes in Table 1).
2. Insert the Key (Item 18) onto the machine shaft keyway.
3. Slide the LSCB onto the machine shaft.
4. Secure the clutch-brake to the machine shaft using the
three Set Screws (Item 16).
5. Attach the air supply line to the air chamber inlet port
and orient in the six o’clock position to avoid water from
accumulating inside the air chamber.
6. Attach an anti-rotation device to the clutch-brake using
one of the two, .250-20 tapped holes located 180°
apart in the air chamber (Item 3). The anti-rotation
device must be capable of absorbing the brake torque
and the design is the responsibility of the machine
designer (See Table 1).
Table 1
Model Size
LSCB-32HT LSCB-44
LSCB-54
Bolt Size
1/4 - 20
1/4 - 20
5/16 - 20
Figure 1
16
16
2
14
1/4-20, two
anti-rotation
fixing holes
180° apart
1/8 NPT air inlet,
orient in the
“six o’clock”
position
CAUTION
Model LSCB is a driven shaft mounted,
clutch-brake with a normally-on (spring
engaged), hub stop brake. This unit design
is not intended to mount on a motor shaft.
NOTE
Nexen pneumatically actuated devices require clean, pressure regulated air for maximum performance and life.
All seals in Nexen Pneumatically operated devices are lubricated for life and do not require additional lubrication.
However, some customers prefer to use an air line lubricator, which injects oil into the pressurized air, forcing an
oil mist into the air chamber. This is acceptable, but care must be taken to ensure once an air mist lubrication
system is used, it is continually used over the life of the product as the oil mist may wash free the factory
installed lubrication.
Locate the lubricator above and within ten feet of the product, and use low viscosity oil such as SAE-10.
Synthetic lubricants are not recommended.
Nexen product's bearings are shielded and pre-lubricated, and require no further lubrication.
LUBRICATOR DRIP RATE SETTINGS
1. Close and disconnect the air line from the unit.
2. Turn the Lubricator Adjustment Knob counterclockwise
three complete turns.
3. Open the air line.
LUBRICATION
CAUTION
These settings are for Nexen supplied
lubricators. If you are not using a Nexen
lubricator, calibration must follow the
manufacturer's suggested procedure.
4. Close the air line to the unit when a drop of oil forms
in the Lubricator Sight Gage.
5. Connect the air line to the unit.
6. Turn the Lubricator Adjustment Knob clockwise until
closed.
7. Turn the Lubricator Adjustment Knob counterclockwise
one-third turn.
8. Open the air line to the unit.
- LSCB-54HT 923627 LSCB-54HT 923625 LSCB-54HT 923624 LSCB-54HT 923591 LSCB-44 923570 LSCB-32HT 923520 LSCB-44HT 923596 LSCB-44HT 923597 LSCB-44HT 923579 LSCB-44HT 923623 LSCB-44HT 923589 LSCB-44HT 923584 LSCB-44HT 923571 LSCB-44HT 923634 LSCB-44HT 923609 LSCB-44HT 923629 LSCB-44HT 923608 LSCB-32 923521 LSCB-44 923572 LSCB-44 923573 LSCB-44HT 923574 LSCB-44 923575 LSCB-54HT 923592 LSCB-54 923593