beautypg.com

Nexen DB 835071 User Manual

Page 7

background image

7

FORM NO. L-20011-J-0711

AIR CONNECTIONS

NOTE

For quick response, Nexen recommends a quick exhaust

valve and short air lines between the Control Valves and

the product. Align the air inlet ports to a down position

to allow condensation to drain out of the air chambers

of the product.

CAUTION

Low air pressure will cause slippage and

overheating. Excessive air pressure will

cause abrupt starts and stops, reducing

product life.

All Nexen pneumatically actuated devices require clean
and dry air, which meet or exceeds ISO 8573.1:2001
Class 4.4.3 quality.

Air Pressure (Gage) Limits

6.9 Bar (100 PSI) Absolute Max.

0 Bar (0 PSI) Absolute Min.

The following is a common air supply scheme used with
this product. This is an example and not an all-inclusive
list. All air circuits to be used with this product must be
designed following EN983 guidelines.

OPTIONAL DB AIR HOSE ASSEMBLY, #835400

Hose Assembly Description:

Hose: 8-inches with swivel nuts on each end. One end
has a tee connector and the other end has an elbow
connector.

Assembly Instructions:

Wrap the 1/8-NPT threads on the elbow and tee with
Teflon sealing tape and install into the brake air inlet ports.

Connection with air supply to the open end of the tee.

This manual is related to the following products: