TROUBLESHOOTING

Symptom

Probable Cause

Solution

Failure to engage

Unexhausted air due to control valve malfunction.

Replace control valve.

Lack of lubrication on Hub spline or in air chamber.

Lubricate Hub spline and check air line
lubricator

Rigid piping or tubing.

Use flexible tubing.

Hub not captured on shaft.

Be sure Set Screws are installed in Hub.

Weak or broken Compression Springs.

Replace Compression Springs.

Failure to disengage

Air not getting to brake due to control valve

malfunction.

Replace control valve.

Hub not captured on shaft.

Be sure Set Screws are installed in Hub.

Friction lock due to lack of lubrication on Hub spline

or in air chamber.

Lubricate Hub spline and check air line
lubricator.

Loss of torque

Weak or broken Compression Springs.

Replace Compression Springs.

Worn or contaminated Friction Facings.

Replace Friction Facings.

Incorrect Friction Facing wear adjustment (QFB only). Perform Friction facing wear adjustment.

Figure 5

Cylinder

Compression

Spring

Pressure Plate

O-Ring

Seals

Shims

Friction Plates

Hub

Drive Disc

Housing

Piston

Friction Facing