Nexen DFE-2500 964009 User Manual
Page 9
FORM NO. L-20021-E-0110
9
NOTE
Nexen pneumatically actuated devices require clean, pressure regulated air for maximum performance and life.
All seals in Nexen Pneumatically operated devices are lubricated for life and do not require additional lubrication.
However, some customers prefer to use an air line lubricator, which injects oil into the pressurized air, forcing an
oil mist into the air chamber. This is acceptable, but care must be taken to ensure once an air mist lubrication
system is used, it is continually used over the life of the product as the oil mist may wash free the factory
installed lubrication.
Locate the lubricator above and within ten feet of the product, and use low viscosity oil such as SAE-10.
Synthetic lubricants are not recommended.
Nexen product's bearings are shielded and pre-lubricated, and require no further lubrication.
LUBRICATOR DRIP RATE SETTINGS
1. Close and disconnect the air line from the unit.
2. Turn the Lubricator Adjustment Knob counterclockwise three
complete turns.
3. Open the air line.
LUBRICATION
CAUTION
These settings are for Nexen supplied
lubricators. If you are not using a Nexen
lubricator, calibration must follow the
manufacturer's suggested procedure.
4. Close the air line to the unit when a drop of oil forms in the
Lubricator Sight Gage.
5. Connect the air line to the unit.
6. Turn the Lubricator Adjustment Knob clockwise until closed.
7. Turn the Lubricator Adjustment Knob counterclockwise one-
third turn.
8. Open the air line to the unit.
AIR CONNECTIONS
CAUTION
Low air pressure will cause slippage and
overheating. Excessive air pressure will
cause abrupt starts and stops, reducing
product life.
All Nexen pneumatically actuated devices require clean
and dry air, which meet or exceeds ISO 8573.1:2001
Class 4.4.3 quality.
The following is a common air supply scheme used with
this product. This is an example and not an all-inclusive
list. All air circuits to be used with this product must be
designed following EN983 guidelines.
NOTE
For quick response, Nexen recommends a quick
exhaust valve and short air lines between the
Control Valves and the product. Align the air inlet
ports to a down position to allow condensation to
drain out of the air chambers of the product.
- QFE-1650 964064 QFE-1650 964046 DFE-1150 964000 DFE-1150 964178 DFE-1150 964043 DFE-1150 964255 DFE-1150 964179 QFE-2200 964066 DFE-2500 964010 DFE-2500 964049 DFE-1150 964001 DFE-1150 964002 DFE-1150 964005 QFE-2200 964067 QFE-2200 964058 QFE-2500 964069 QFE-1150 964060 QFE-1150 964093 QFE-2500 964070 QFE-2500 964047 QFE-1150 964061 QFE-1150 964041 QFE-1150 964062 DFE-1650 964003 DFE-1650 964050 DFE-1650 964203 DFE-1650 964057 DFE-1650 964042 DFE-1650 964048 DFE-1650 964304 DFE-1650 964004 DFE-1650 964024 DFE-1650 964056 DFE-1650 964044 DFE-1650 964027 DFE-2200 964006 QFE-1650 964063 DFE-2200 964007 DFE-1150 964016 DFE-1650 964019 DFE-2200 964022 DFE-2500 964025 QFE-1150 964088 QFE-1650 964091 QFE-2200 964094 QFE-2500 964097