CLEARANCES

Minimum clearances in inches to combustible
materials are:

G :

Top 0

K: Side 0
L: Bottom 0

M: Rear 1

Clearance M between the rear-most part of the
refrigerator and the wall behind the refrige-

rator.

Clearance N on top of the condenser is related

to the minimum ventilation height.
See Fig. 5 and examples below.

Fig.5

MEASUREMENTS

Distance

Refrigerator Overall Installation

Recess

between top

dimensions dimensions

dimensions

of condenser

model to top of

Height Width Depth Height Width Depth Height Width

Depth

refrigerator

A B C h

W

d H

W D e

RM360

30 3/8

21 11/16 22 1/16

29 9/16

20 1/4

20 3/16 29 3/4

20 1/2

21 3/16

1 1/4

RM460

32 15/16 23 24 11/16 32 1/8

21 9/16

22 3/4

32 5/16 21 13/16 23 3/4

1 1/4

RM660

40 13/16 23 24 11/16 40 21 9/16

22 3/4

40 3/16 21 13/16 23 3/4

1 1/4

RM760

52 23 24 11/1

51 3/16

21 9/16

22 3/4

51 3/8

21 13/16 23 3/4

1/8

Storane volumes

Refrigerator Total storage volume in cu ft
model

RM360

3.0

RM460

3.9

RM660

5.1

RM760

6.0

EXAMPLES

The clearance N for the RM360 model is derived

in the following way:

at

A. Installation with upper and lower side vents.

N=Minimum ventilation height 37 minus in-

stallation height 29 9/16 plus distance

between condenser top and refrigerator top

1 l/4

N=37-29 9/16+1 l/4=8 11/16.

B. Installation with roof vent and lower side

vent.

N=Minimum ventilation height 31 minus in-

stallation height 29 9/16 plus distance

between condenser top and refrigerator top

1 l/4 plus distance between roof surface

and roof vent cap 5 l/4.

N=31-29 9/16+1 l/4+5 l/4=7 15/16.