beautypg.com

DSC POWERSERIES PC1616 User Manual

Page 9

background image

5

Disarming Error

If your code is invalid, the system will not disarm and a 2-second error tone will sound. If this hap-
pens, press

and try again.

Stay Arming (Partially Turning On / Part Setting)

Ask your alarm company if this function is available on your system.
Stay arming will bypass the interior protection (i.e. motion sensors) and arm the perimeter of the sys-
tem (i.e. doors and windows). Close all sensors (i.e. stop motion and close doors). The Ready (

)

indicator should be on.
Press and hold the Stay key (

) for 2 seconds and/or enter your Access Code and do not leave

the premises (if your installer has programmed this button). During the setting state (exit delay
active), the Armed ( ) and Ready (

) indicators will turn on.

When the exit delay is completed, the alarm system is armed/set and this is indicated on the keypad
as follows: the Ready (

) indicator will turn off, the Armed (

) indicator will remain on and the key-

pad will stop sounding. The Armed (

) indicator and Bypass or System indicator will turn on. The

system will automatically bypass certain interior sensors (i.e. motion sensors).

SIA NOTE:

For SIA FAR listed panels, the Stay Arming Exit Delay will be twice as long as the

Away Arming Exit Delay.

Night Arming

To fully arm the system when it has been armed in Stay Mode, press [

✱][1] at any keypad. All interior

zones will now be armed except for devices programmed as Night Zones. Night zones are only armed
in Away mode, this permits limited movement within the premises when the system is fully armed.
Ensure that your installer has provided you with a list identifying zones programmed as night zones.
When the interior zones have been activated (i.e., (*)(1) you must enter your access code to disarm
the system to gain access to interior areas that have not been programmed as night zones.

Silent Exit Delay

If the system is armed using the Stay key (

) (Programmable Function Key) or using the "No

Entry" Arming method (

[access code]), the audible progress annunciation (keypad buzzer) will

be silenced, and the exit time will be doubled for that exit period only (CP-01 versions only).

NOTE:

For non CP-01 versions, Standard Exit Time is used.

Remote Arming and Disarming

The system can be armed and/or disarmed using the remote control device (wireless key). When arming
the system by using the Arm button on the wireless key, the system will acknowledge the command by
sounding a single bell squawk (if bell squawk is enabled) and when disarming using the Disarm button
on the wireless key the system will acknowledge the command by sounding two bell squawks (if bell
squawk is enabled) that can be heard from the exterior of the premises.

Emergency Keys

Press the

(F),

(A) or

(P) key for 2 seconds to generate a Fire, Auxiliary or Panic alarm. The key-

pad sounder will beep indicating that the alarm input has been accepted and transmission to the cen-
tral station is underway. Ask your alarm company if the emergency keys are available on your system.

NOTE:

The Fire keys can be disabled by the installer.

LED5511/LCD5511 Keypad

Press and hold both keys simultaneously for 2 seconds to send the following messages:

Fire Message,

Auxiliary Message,

Panic Message.

When Alarm Sounds

The system can generate 4 different alarm sounds:

• Temporal / Pulsed Siren = Fire Alarm
• 4 beeps, 5-second pause, 4 beeps = Carbon Monoxide Alarm
• 5 beeps at keypad = Medical Alarm
• Continuous Siren = Intrusion (Burglary Alarm)

NOTE:

The priority of signals is fire alarm, carbon monoxide alarm, medical alarm then burglary

alarm.

This manual is related to the following products: