Owner’s manual, Venting installation – Desa DVFE34 User Manual

Page 7

background image

7

107205

OWNER’S MANUAL

For more information, visit www.desatech.com

WARNING: Read all instruc-

tions completely and thoroughly
before attempting installation. Fail-
ure to do so could result in serious
injury, property damage or loss of
life. Operation of improperly in-
stalled and maintained venting sys-
tem could result in serious injury,
property damage or loss of life.

WARNING: Seal all vent con-

nections. Seal only the outer pipe
connections with high temperature
silicone (600

°

F/316

°

C). Before join-

ing elbows and pipes, apply a bead
of high temperature silicone seal-
ant (GE RTV 106/Loctite RTV 81585)
to the male end of the elbow or
pipe. High temperature silicone
must also be used to re-seal any
connections after maintenance to
venting system.

NOTICE: Failure to follow these
instructions will void the warranty.

INSTALLATION PRECAUTIONS

Consult local building codes before begin-
ning the installation. The installer must make
sure to select the proper vent system for
installation. Before installing vent kit, the
installer must read this fireplace manual and
vent kit instructions.

Only a qualified service person should in-
stall venting system. The installer must fol-
low these safety rules:

• Wear gloves and safety glasses for

protection

• Use extreme caution when using ladders

or when on roof tops

• Be aware of electrical wiring locations

in walls and ceilings

The following actions will void the war-
ranty on your venting system:

• Installation of any damaged venting

component

• Unauthorized modification of the vent-

ing system

VENTING
INSTALLATION

WARNING: This gas fireplace

and vent assembly must be
vented directly to the outside.
The venting system must NEVER
be attached to a chimney serving
a separate solid fuel burning ap-
pliance. Each gas appliance must
use a separate vent system. Do
not use common vent systems.

WARNING: Horizontal sec-

tions of this vent system require a
minimum clearance of 2" from the
top of the pipe and 1" minimum to
the sides and bottom. 1

1

/

2

" clear-

ance is required where termina-
tion penetrates a combustible wall.
Vertical sections of this system
require a minimum of 1" clear-
ance to combustible materials on
all sides of the pipe.

• Installation of any component part not

manufactured or approved by DESA
International

• Installation other than as instructed by

these instructions

INSTALLATION PLANNING

There are two basic types of direct-vent
installation:

• Horizontal Termination

• Vertical Termination

It is important to select the proper length of
vent pipe for the type of termination you
choose. It is also important to note the wall
thickness.

For Horizontal Termination:

Select the

amount of vertical rise desired. The horizon-
tal run of venting must have 1/4" rise for
every 12" of run towards the termination.

NOTICE: Treatment of firestops
and construction of the chase may
vary from building type to building
type. These instructions are not
substitutes for the requirements
of local building codes. You must
follow all local building codes .

Note:

When installing in a chase, you should

insulate the chase as you would the outside
walls of your home. This is especially im-
portant in cold climates. Minimum clear-
ance between vent pipes and combustible
materials such as insulation is 1".

After framing the chase (see Framing and
Finishing
on page 4) install the vent system
by following the installation instructions.

Installing Vent System in a Chase

A chase is a vertical boxlike structure built
to enclose venting that runs along the out-
side of a building. A chase is not required for
such venting.

Continued

WARNING: Never run the vent

downward as this may cause ex-
cessive temperatures which
could cause a fire.

You may use one or two 90

°

elbows in this

vent configuration. See Horizontal Termina-
tion Configurations
on pages 10 and 11.

For Vertical Termination:

Measure the dis-

tance from the fireplace flue outlet to the
ceiling. Add the ceiling thickness, the verti-
cal rise in an attic or second story, and allow
for sufficient vent height above the roofline.
You may use one or two 90

°

elbows in this

vent configuration. See Vertical Termination
Configurations
on pages 13 and 14.

Note:

You may use two 45

°

elbows in place

of a 90

°

elbow. You must follow rise to run

ratios when using 45

°

elbows.

For two-story applications, firestops are re-
quired at each floor level. If an offset is
needed in the attic, additional pipe and el-
bows will be required.

You may use a chase with a vent termination
with exposed pipe on the exterior of the house.
See Installing Vent System in a Chase, below.

Your FMI direct-vent fireplace has been tested
for a minimum 3' rise with a maximum 10"
wall thickness. The maximum horizontal run
is 20' with 8' vertical rise (see Installation for
Horizontal Termination
, page 8). The maxi-
mum vertical run is 30' (see Installation for
Vertical Termination
, page 12).

It is very important that the venting system
maintain its balance between the combus-
tion air intake and the flue gas exhaust.
Certain limitations apply to vent configura-
tions and must be strictly followed.