DIRECT-VENT FIREPLACE

For more information, visit www.desatech.com

INSTALLING OPTIONAL
BLOWER ACCESSORY

IMPORTANT

: For clarity, gas valve assem-

bly and grate/burner assembly are not shown
in Figures 29 through 32, page 17. They will,
however, be in your fireplace when you are
installing the blower. Also for clarity the
firebox is shown with dotted lines.

1.

Open lower louver panel or remove for
easier access.

2.

Place the blower against the lower rear
wall of firebox outer wrapper with the
exhaust port directed upward. Align the
holes in the top mounting tabs of
blower with holes in wall of wrapper
(see Figure 29, page 17). Using the two
screws provided, mount blower and
tighten screws securely.

Note:

For DA3610TA, make sure the

thermal switch is comfortably under the
back of the firebox as shown in Figure
30, page 17.

3.

Be sure to securely attach all wire ter-
minals to terminals on blower motor
(and thermal switch where applicable)
and that the screw retaining the green
ground wire is tight.

4.

Remove screws securing the plate to
the bottom of the firebox and set aside.

5.

Place speed control against back of this
plate and push the plastic control shaft
through opening (see Figure 31, page 17).

6.

While supporting speed control, secure
control shaft with lock nut by pushing and
turning lock nut with pliers clockwise
until tight against the plate. Place control
knob provided onto shaft (see Figure 31,
page 17).

7.

Replace plate containing switch and
tighten screws securely.

NOTICE: If installing blower in an
existing fireplace with gas con-
nections, shut off gas supply and
disconnect heater from gas sup-
ply. Contact a qualified service
person to do this.

CHECK GAS TYPE

Use proper gas type for the fireplace unit
you are installing. If you have conflicting
gas types, do not install fireplace. See re-
tailer where you purchased the fireplace for
proper fireplace according to your gas type.

FIREPLACE
INSTALLATION

NOTICE: This fireplace is in-
tended for use as supplemental
heat. Use this fireplace along with
your primary heating system. Do
not install this fireplace as your
primary heat source. If you have
a central heating system, you may
run system’s circulating blower
while using fireplace. This will
help circulate the heat through-
out the house. In the event of a
power outage, you can use this
fireplace as a heat source.

WARNING: A qualified installer

or service person must install fire-
place. Follow all local codes.

CAUTION: This fireplace cre-

ates warm air currents. These cur-
rents move heat to wall surfaces
next to fireplace. Installing fire-
place next to vinyl or cloth wall
coverings or operating fireplace
where impurities (such as to-
bacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
discolor walls.

Note:

Your fireplace is designed to be used

in zero clearance installations. Wall or fram-
ing material can be placed directly against
any exterior surface on the rear, sides, or top
of your fireplace, except where standoff
spacers are integrally attached. If standoff
spacers are attached to your fireplace, these
spacers can be placed directly against wall
or framing material. See framing details on
page 4.

Place the fireplace into position and shim
with noncombustible material if needed.
Nail the side flanges to the framing to secure
the unit in place. There are two floor brack-
ets included with each unit. Use these as an
alternative method of securing the fireplace.

IMPORTANT:

Make sure fireplace is level

before securing. If fireplace is not level it
will not work properly.

Attaching Thermal Switch to
DA3610TA Thermostatically-
Controlled Blower

When installing the DA3610TA thermo-
statically-controlled blower accessory, you
must first secure the thermal switch to the
blower.

1.

Remove the two hex head screws on the
blower assembly as shown in Figure 28.

2.

Place the green wire between the bot-
tom hole on the thermal switch bracket
and the bottom hole on the blower as-
sembly. Insert one of the hex screws
into all three pieces and tighten.

3.

Insert the top screw through the ther-
mal switch bracket and into the blower
assembly. Tighten screw.

4.

Connect the blue wire on the blower
assembly to the right side of the ther-
mal switch.

5.

Connect the black wire to the left side
of the thermal switch.

Installing GA3700/DA3610TA
Blowers

Figure 28 - Attaching Thermal Switch to DA3610TA Thermostatically-Controlled
Blower Accessory

Blower Assembly

Blue Wire

Green Wire

Black Wire

White Wire

Hex Head
Screws

Thermal Switch
with Bracket