beautypg.com

Trouble shooting flow chart, Power circuit – Daewoo DV-K580NZ-T User Manual

Page 25

background image

24

TROUBLE SHOOTING FLOW CHART

1. POWER CIRCUIT

When changing the parts which are broken first, remove the power plug from the socket and then discharge the voltage
across the terminals of C806. (Use an external K

resistance)

When check the primary circuit , use the oscilloscope isolated properly (Use the isolated transformer) and connect
GND to the primary GND, however it is not necessary to isolate the oscilloscope when check the secondary circuit.

A. CHECKING THE PRIMARY CIRCUIT

No output Voltage.

NO

NO

Prepare the oscilloscope

connected the isolated

Transformer.

Check L801.

Check M801 Power Module,

D801

YES

YES

YES

YES

YES

Check F801 Fuse.

Is voltage applied to D801?

Is voltage applied to the

terminals of C806?

Check the Secondary circuit