beautypg.com

Daewoo DV-K580NZ-T User Manual

Page 13

background image

12

ELECTRICAL ADJUSTMENT

(6) Y RECORD CURRENT

v

CONNECTION METHOD

v

ADJUSTMENT PROCEDURE

1) Supply the Color Bar Signal to the VIDEO IN JACK.
2) After Inserting a Rec Tape, Rec in SP MODE.
3) Connect the oscilloscope to TJ491

and trigger the scope with a compos-
ite sync signal at TJ302.

4) Adjust R491 until Y-FM record current

is 500

±

10mVp-p. (Standard SYNC

Tip)

Adjustment Parts

Checking Point

Measuring Equipment

Test Tape

Input Signal

R491

TJ491

Signal Gen. Oscilloscope

Blank Tape

Color Bar

REC-Y

TJ302

CH-1
Oscilloscope
CH-2

SIGNAL
GENERATOR

TJ491

R491

500V 10mVp-p

TJ491