beautypg.com

Daewoo DV-K580NZ-T User Manual

Page 22

background image

21

CIRCUIT OPERATION

3-3) TERMINAL PART

ALARM INPUT
Connect DOOR SW&SENSOR etc and this port will be used for emergency recording by using open/close status.

ALARM OUTPUT
This port is always triggered during ALARM REC, which is used to inform the outside that time lapse VCR is now perform-
ing Alarm Recording.

u Trigger Time will be the set time on MENU, it will be approximately 2 minutes at least.

PANIC INPUT
This is the first priority REC, then operation is similar as Alarm Rec. But if Panic Recording is triggered, the set stops all
kinds of Recording then starts recording with 2H(SP) mode at the end of tape.

5V

0V

500ms

500ms

N/O(NORMALY OPEN)

N/C(NORMALY CLOSED)

0V

5V

0V

Minimum 2mins.

Minimum 2mins.

HIGH

LOW

5V

0V

500ms

500ms

N/CLOSED

N/OPEN

5V