Vertical dimensional data cont, Vertical disconnect, Versatec base series installation manual – WaterFurnace Versatec Base User Manual
Page 7

7
VERSATEC BASE SERIES INSTALLATION MANUAL
Vertical Dimensional Data cont.
Alternative
Power Supply
Disconnect Located
on this Side for a
Right Return
Disconnect
Location
Vertical Shown in Left
Return Configuration
Power
Supply
LL
Vertical Models
LL
015-018
15.8 [40.1]
024-030
18.8 [47.8]
036
15.3 [38.9]
042-048
13.8 [35.1]
060
14.3 [36.3]
070
14.3 [36.3]
Dimensions in inches [cm]
* Models 006-012 - Externally Mounted Disconnect
Vertical Disconnect
When using disconnect, do not use dimension L from the
standard vertical dimensional data. Use dimension LL from
the vertical disconnect dimensional data.
Condensate is 3/4 in. PVC female glue socket and is switchable from side to front.
* Discharge fl ange is fi eld installed and extends 1 in. (25.4 mm) from top of cabinet.
** Vertical units shipped with standard 2 in. (fi eld adjustable to 1 in.) open application fi lter rail extending 2.2 in. from the unit and
is not suitable for duct connection. For ductable return connection applications, order the 2 in. (fi eld adjustable to 1 in.) duct collar/
fi lter rack which extends to 3.25 in. from the unit and is suitable for duct connections.
Vertical
Models
Overall Cabinet
Water Connections
Electrical Knockouts
6
7
8
1
2
5
Loop
J
K
L
A
B
C
D
E
H
1/2 in. cond 1/2 in. cond 1 in. cond
M
Width
Depth
Height*
In
Out
Cond-
ensate
Water FPT
Low
Voltage
Low
Voltage
Power
Supply
Filter Rack
Width
006-012
in.
19.2
19.2
24.2
2.6
5.6
8.8
1/2 in.
7.4
3.4
5.4
2.2
cm.
48.8
48.8
61.5
6.6
14.2
22.4
12.7 mm
18.8
8.6
13.7
5.6
015-018
in.
22.5
22.2
30.2
2.6
7.6
10.8
3/4 in.
9.4
5.4
7.4
2.2
cm.
57.2
56.4
76.7
6.6
19.3
27.4
19.1 mm
23.9
13.7
18.8
5.6
024-030
in.
22.5
22.2
36.2
2.6
7.6
10.8
3/4 in.
9.4
5.4
7.4
2.2
cm.
57.2
56.4
91.9
6.6
19.3
27.4
19.1 mm
23.9
13.7
18.8
5.6
036
in.
22.5
26.2
40.2
2.6
7.6
10.8
3/4 in.
10.1
6.1
8.1
2.2
cm.
57.2
66.5
102.1
6.6
19.3
27.4
19.1 mm
25.7
15.5
20.6
5.6
042-048
in.
22.5
26.2
44.2
2.6
7.6
10.8
3/4 in.
10.1
6.1
8.1
2.2
cm.
57.2
66.5
112.3
6.6
19.3
27.4
19.1 mm
25.7
15.5
20.6
5.6
060
in.
25.5
31.2
44.2
2.6
7.6
10.8
1 in.
10.1
6.1
8.1
2.2
cm.
64.8
79.2
112.3
6.6
19.3
27.4
25.4 mm
25.7
15.5
20.6
5.6
070
in.
25.5
31.2
48.2
2.6
7.6
10.8
1 in.
10.1
6.1
8.1
2.2
cm.
64.8
79.2
122.4
6.6
19.3
27.4
25.4 mm
25.7
15.5
20.6
5.6
Vertical
Models
Discharge Connection
duct fl ange installed (±0.10 in)
**Return Connection
using deluxe fi lter rack (±0.10 in)
N
P
Q
R
S
T
U
V
W
Supply Width Supply Depth
Return Depth Return Height
006-012
in.
10.0
10.0
4.6
4.4
7.8
2.4
14.3
10.1
2.0
cm.
25.4
25.4
11.7
11.2
19.8
6.1
36.3
25.7
5.1
015-018
in.
14.0
14.0
4.1
4.3
7.7
2.1
18.1
14.0
2.0
cm.
35.6
35.6
10.4
10.9
19.6
5.3
46.0
35.6
5.1
024-030
in.
14.0
14.0
4.1
4.3
7.7
2.1
18.1
20.0
2.0
cm.
35.6
35.6
10.4
10.9
19.6
5.3
46.0
50.8
5.1
036
in.
14.0
14.0
6.1
4.5
7.7
2.1
22.1
22.1
2.0
cm.
35.6
35.6
15.5
11.4
19.6
5.3
56.1
56.1
5.1
042-048
in.
18.0
18.0
4.1
3.9
3.9
2.1
22.1
26.1
2.0
cm.
45.7
45.7
10.4
9.9
9.9
5.3
56.1
66.3
5.1
060
in.
18.0
18.0
6.6
4.6
6.3
1.6
28.1
26.0
2.0
cm.
45.7
45.7
16.8
11.7
16.0
4.1
71.4
66.0
5.1
070
in.
18.0
18.0
6.6
4.6
6.3
1.6
28.1
30.0
2.0
cm.
45.7
45.7
16.8
11.7
16.0
4.1
71.4
76.2
5.1
09/26/12