beautypg.com

Envelope section – Waldorf 2-Pole User Manual

Page 26

background image

2-pole Parameters

2-pole Analog Filter User´s Manual

26

Envelope Section

The 2-pole Filter offers an envelope that can be triggered
from various sources.

Mode Selector

The Mode Selector determines the trigger
behaviour of the envelope.

Pulse Trigger (topmost setting) genera-
tes a short pulse that can be retriggered after
the Hold Time setting. You can set the

trigger sensitivity by using the Threshold control.

w

In this mode, keep Attack close to the minimum to
let the envelope the time to rise.

Gate Trigger (middle setting) generates a continous

state that lasts as long as Hold Time. You can set the
trigger sensitivity by using the Threshold control.
Hold Time

can lenghten the trigger time, if necessary.

Envelope Follower (downmost setting) means, that

the filter envelope is driven by the input signal itself.
Threshold

and Hold Time have no influence at all.

w

To disable the trigger system, set Mode to Pulse
Trigger

, Threshold and Hold Time to zero.

Attack

Determines the attack rate or amount of
time it takes for the envelope to rise.