3. Specifications

IEC 1010 Over Voltage:

CAT II - 1000V

CAT III - 600V

Pollution Degree 2

Temperature for gauranteed accuracy: 23ºC +5ºC

DC VOLTS

Range

Res.

Accuracy

110mV

0.1mV

Impedance:

1V

0.001V

+/-(0.5% of reading + 2 digits)

10M

11V

0.01V

Overload Protection:

110V

0.1V

600VDC or AC RMS

600V

1V

(45Hz to 100Hz Frequency Response 400mV Range

)

AC VOLTS

(45Hz to 450Hz Frequency Response All Other Ranges)

Range

Res.

Accuracy

110mV

0.1mV

+/-(1.2% of reading + 5 digits)

Impedance:

1V

0.001V

+/-(1.2% of reading + 3 digits)

10M

11V

0.01V

Overload Protection:

110V

0.1V

+/-(1.5% of reading + 3 digits)

600VDC or AC RMS

600V

1V

8

DC Microamps

Range

Res.

Accuracy

110uA

0.01

µA

+/-(0.8% of reading + 2 digits)

Overload Protection:

1100uA

0.1

µA

0.5A / 600V Fuse

e

* DC microamps are measured with the test leads in series with

the circuit under test.

DC AMPS

Range

Res.

Accuracy

110A

0.01A

+/-(

3% of reading + 10 digits)

400A

0.1A

e

OHM (

Resistance,

Ω)

Range

Res.

Accuracy

110

0.

01Ω

±(1% of reading +5 digits)

1k

0.

0001kΩ

±(1% of reading +2 digits)

Overload Protection:

11k

0.

001kΩ

250VDC or AC RMS

110k

Ω 0.01kΩ

1M

0.

0001MΩ

±(3% of reading +5 digits)

11M

0.

001MΩ

±(3% of reading +10 digits)

110M

Ω 0.1MΩ

±(3% of reading +10 digits)

Frequency (Hz)

Range

Res.

Accuracy

11

00.0Hz 0.1Hz

±(1% of reading +2 digits)

11.000kHz 0.001kHz
110.00MHz 0.01kHz

Overload Protection:

1.1000MHz 0.0001MHz

250VDC or AC RMS

11.000MHz 0.001MHz
110.00MHz 0.01MHz

UL 3111 Pending

(45Hz to 100Hz Frequency Response 200A to 400A)

AC AMPS

(45Hz to 450Hz Frequency Response Below 200A)

Range

Res.

Accuracy

110A

0.01A

+/-(3.0% of reading + 5 digits)

400A

0.1A

e

Warning:

Use only correct type and overvoltage
category rated test leads. Remove the
temperature probe when using the test
leads or amp clamp.