Data Output Connection
To connect an output cable, remove the two small Phillips screws as shown below.
Then, remove the output port cover.
Plug in the cable and secure it with the same screws that held the cover. Orient the
data cable plug as shown below. When not using output, replace the data cover to
protect the electronics
Battery Replacement
Remove the two Phillips screws that secure the battery drawer
as shown below.
Remove the battery drawer and discard the old batteries.
Place two new CR2032 batteries into the tray with the positive (+) side facing up. Slide
the tray carefully into the indicator and secure with the two screws.
To order CR2032 batteries, specify: PT99492. EDP 65650