Connection & setting, Specifications – SkyRC 2S 10A Linear Voltage Regulator User Manual
Page 2
CONNECTION & SETTING
Connect Pin-Flag power switch (SK-600052) if you are using it on the “switch” connector. It is not necessary to use
a switch as the unit uses Fail Safe “On” system, meaning it will automatically power up when plugged to the
batteries if no switch is attached.
Setup the output voltage. You can use the DIP switch on the back to setup the output voltage. In that case, put the
DIP switch for the desired voltage in “ON” position (up) and keep others on “OFF” position. Only one switch must be
in “ON” position at a time. Factory default is set on 6.0V
Battery Low voltage Alarm: You can set it up between 6.6v and up to 7.4V by using the “Alarm-ADJ”. This will light
up the Pin-Flag power switch with ultra bright super flux LED. Initial setting of this unit low voltage alarm is around
7.3V.We recommend you to make a test flight and set the Low Voltage Alarm at the end of your flight and then fine
tune on the next 2 or 3 flights. Please take into consideration that the settings might need to be changed depending
of the LiPo you will be using.
Fit the unit and connect your system wires. Double check all wires and perform a on the bench to check that
everything is OK. We also recommend you to perform the basic security tests on your RC model before initial and
inspect before each flight that all servos and equipment are responding correctly.
7504-0256-02
Manufactured by
SKYRC TECHNOLOGY CO., LTD.
www.skyrc.com
Please find a place with good airflow to install the regulator
Don't put any electronics on the heat sink of the regulator.
Due to the vibration during flight, please make sure the cables are fixed well to the regulator.
Don't disassemble the regulator by yourself or you will not enjoy our free repair service.
The regulator still consumes small current even if the regulator is OFF. So please disconnect the battery to the
regulator if you don't use it.
WARNING AND SAFETY NOTES
1)
2)
3)
4)
RX
ESC
MOTOR
2S LiPo
Battery
Source
VOLTAGE
OUTPUT PLUG
INPUT POWER
CONNECTION
REMOVE THE
POSITIVE ESC
CONNECTION
TO THE RX
5.2 volts setting
6.0 volts setting
Default
6.8 volts setting
7.4 volts setting
Set alarm ON
Set alarm OFF
Default
Alarm Switch
6.8V
6.0V
5.2V
Input Voltage: 6.0-8.4V(2 LiPo Cells)
Output Voltage: 5.2V-7.4V Selectable
Low Battery Alarm Voltage: 6.6V-7.4V
Model: SK-600049
www
.skyrc.com
INPUT
S
SW
AUX
S
Low Voltage
Alarm-ADJ
ON
OFF
LINEAR VOLTAGE REGULATOR
OUT
1
2
3
4
ON
YELLOW
WHITE
RED
BLACK
Connect to
Pin-Flag Power Switch
Input: 2S LiPo (6.0 to 8.4Volt)
Output: 5.2V 6.0V 6.8V 7.4V 10A@6V(Peak 15A@6V)
Adjustable Low Voltage Alarm Setup : 6.6-7.4V
Switch Type : Fail Safe(Fail-Safe-On) Pin-Flag Contactless Type
Size : 13.8mm(H) x 31mm(W) x 54mm(L) Weight : 37g (Excluding Cables)
Contents : Main Unit 1PC, Power Switch 1PC, Operating Manual 1PC
SPECIFICATIONS
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4