Connection & setting, Specifications – SkyRC 14S 10A BEC User Manual
Page 2
CONNECTION & SETTING
Connect Pin-Flag power switch (SK-600052) if you are using it on the “switch” connector. It is not necessary to use a switch as
the unit uses Fail Safe “On” system, meaning it will automatically power up when plugged to the batteries if no switch is
attached.
Setup the output voltage. You can use the DIP switch on the back to setup the output voltage. In that case, put the DIP switch for
the desired voltage in “ON” position (up) and keep others on “OFF” position. Only one switch must be in “ON” position at a time.
IF you put all switches in “OFF” position the selected voltage will be then 8.4V. Factory default is set on 6.0V.
Battery Low voltage Alarm: You can set it up between 10V and up to 60V by using the “Alarm-ADJ” potentiometer for coarse
setup and then fine tune with the “Fine-ADJ” potentiometer. This will light up the Pin-Flag power switch with ultra bright super
flux LED. Initial setting of this unit low voltage alarm is around 36V. We recommend you to make a test flight and set the Low
Voltage Alarm at the end of your flight and then fine tune on the next 2 or 3 flights. Please take into consideration that the
settings might need to be changed depending on the LiPo you will be using. If you want to disable the Low Voltage Alarm
function, you can turn it by turning the “Alarm-ADJ” potentiometer fully counter clockwise (Be careful to not turn the
potentiometer too hard or you will damage it).
Fit the unit and connect your system wires. Double check all wires and perform once on the bench to check that everything is
OK. We also recommend you to perform the basic security tests on your RC model before initial and inspect before each flight
that all servos and equipment are responding correctly.
7504-0278-01
Manufactured by
SKYRC TECHNOLOGY CO., LTD.
www.skyrc.com
Please find a place with good airflow to install the regulator.
Don't put any electronics on the heat sink of the regulator.
Due to the vibration during flight, please make sure the cables are fixed well to the regulator.
Don't disassemble the regulator by yourself or you will not enjoy our free repair service.
The regulator still consumes small current even if the regulator is OFF. So please disconnect the battery to the
regulator if you don't use it.
WARNING AND SAFETY NOTES
1)
2)
3)
4)
RX
ESC
MOTOR
3-14S LiPo
Battery
Source
VOLTAGE
OUTPUT PLUG
INPUT POWER
CONNECTION
REMOVE THE
POSITIVE ESC
CONNECTION
TO THE RX
YELLOW
WHITE
RED
BLACK
Connect to
Pin-Flag Power Switch
Input: 3-14S LiPo (11.1 to 60Volt)
Output: 5.2V 6.0V 6.8V 7.4V 8.4V 10A@6V(Peak 15A@6V)
Adjustable Low Voltage Alarm Setup : 10-60V
Switch Type : Fail Safe(Fail-Safe-On) Pin-Flag Contactless Type
Size : 15.7mm(H) x 31mm(W) x 54mm(L) Weight : 45g (Excluding Cables)
Contents : Main Unit 1PC, Power Switch 1PC, Operating Manual 1PC
SPECIFICATIONS
Model: SK-600053
www
.skyrc.com
INPUT
S
SW
AUX
S
ON
OFF
OUT
1
2
3
4
ON
7.4V
6.8V
6.0V
5.2V
Input Voltage: 11.1-60V(3-14 LiPo Cells)
Output Voltage: 5.2V-8.4V Selectable
Low Battery Alarm Voltage: 10V-60V
SUPER BEC
(Synchronous Rectification)
Low Voltage
Alarm-ADJ
Fine
-ADJ
5.2 volts setting
6.0 volts setting
Default
6.8 volts setting
7.4 volts setting
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
8.4 volts setting