11. Close the pressure regulator. Rotate the regulator knob (F)

counter-clockwise to its built-in stop and push knob in to lock in

place. This will allow air to build pressure in the air tank.

12. Compressed air will be available from the hose air outlet until it is

used up or bled off.

oPErATInG ProCEDurES
Start-up (Fig. 1)

WARNING: Do not operate this unit until you read and understand

this instruction manual and the engine instruction manual for safety,

operation and maintenance instructions.
1. Follow

Pre-start Checklist under Preparation for Use.

2. Pull out and turn regulator knob (F) counter-clockwise until fully

closed. Push in to lock. Regulated pressure gauge should read

0 psi.

3. Rotate the manual lock unloader lever to the

open position to

assist with start up.

4. Place the fuel valve lever (O) in the ON postion.
5. If the engine is cold, move the choke (N) to the CLOSED position

as shown. If the engine is hot, move the choke to the OPEN

position.

6.

recoil start:

a. Turn the engine START/RUN/OFF switch (C) to the RUN

position.

b.

WARNING: Risk of unsafe operation. Pull starter grip slowly

until resistance is felt. Then pull starter grip (P) rapidly to avoid

kickback and prevent hand or arm injury.

note: Do not allow the starter grip to snap back. Return it gently

by hand.

electric start

a. Remove cap from 18V battery pack (Q) and plug battery

power pack into battery receptacle. Close battery cover over

battery and lock (U) into place, if desired (lock not included).

note: Make sure your battery pack is fully charged. See Charger

Procedure for charging procedure.
b. Place engine START/RUN/OFF switch (C) in the START

position and hold until the engine starts.

note: Do not hold the switch in the START position for more than 5

seconds. If the engine does not start, wait 10 seconds before retry-

ing. Failure to follow these instructions may result in damage to the

starter motor due to overheating.
c. When the engine starts, release the engine switch allowing it

to return to the RUN position.

note: Do not turn the engine switch to the START position while

the engine is running.
note: If the oil level in the engine is low, the engine will not start.

If the engine does not start, check the oil level and add oil as

needed.
note: To ensure maximum oil lubrication, place the unit on a level

surface.
7. As the engine warms up, move the choke to the OPEN position.
8. Rotate manual lock unloader lever to the

closed position to allow

air tank pressure to build.

note: Pump will not operate with the

manual lock unloader lever in the

open position.

9. Allow compressor to pump up to

blow off pressure.

note: If any unusual noise or vibration is noticed, stop the compressor

and refer to the troubleshooting section.
note: The air compressor pump is capable of running continuously.

To prolong the air compressor's life, it is recommended to run at high

throttle 50-75% of the run time and idle for 25% of the run time.