REFCO GOBI User Manual
Page 6

2
3
4
5
6
7
1
9
10
11
12
13
14
8
16
17
18
19
20
15
1
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
30
40
50
10
60
20
0
0
0
0
Vertical lift
(m)
(ft)
Flowrate
(l/h)
(USgal/h))
0m Horiz
50m Horiz
100m Horiz
Capacity
Specifications
Power supply:
120/240Vac, 50/60Hz Auto sensing
Power consumption:
16W max., 0.25W when idle
Alarm relay:
5A, 30Vdc, 250Vac Break on fault
Capacity:
12 litres/hour max. (3.17 US gal/h)
Maximum head:
Vertical >20m (65 ft), Horizontal >100 m
(328 ft) Suction 1 m max. (3.28 ft)
Ambient temp:
0 - 40°C
Water temp:
25°C max.
Material:
Flame retardant ABS UL94 5VA
Discharge tube:
6mm (1/4”) ID
Dimensions:
286 x 61 x 53mm (11.3” x 2.4” x 2”)
IP:
44
Trouble Shooting
Pump does not run:
Pump is pumping air:
Check fuse and electrical supply
connections.
Check that water is reaching the pump
sensor.
Check that the collection tray is level.
Check that the sensor is clean and
undamaged.
Check that the outlet tube is not
syphoning.
Pump is noisy:
Pump continues to run with no water:
Check that the mains cable and outlet tube
are not vibrating against the sides of the
equipment.
The sensor may be contaminated by dirt,
mould or certain cleaning chemicals. Gently
wipe the sensor with a damp cloth. If the
problem persists, repeat with methylated
spirit and then rinse with water.
5
GB