Save these instructions, Mounting options, Types of mounting – Paraclipse Terminato User Manual
Page 4: Ceiling mounted: (fig. 2), Table mounting: (fig. 3), Do not install, Paraclipse ™ terminator, Ultraviolet lamp insertion, Grill removal and installation: (fig. 4)
Save these instructions
Page 4
MOUNTING OPTIONS
Types of mounting:
Your Paraclipse ™ Terminator can be mounted
two different ways, to best fit your application.
1. Ceiling mounted: (fig. 2)
Using the chain and S hooks supplied mount your
trap to ceiling supports.
Note:
When mounting your Paraclipse ™ Ter-
minator to the ceiling be certain to take into ac-
count the trap location and suitable ceiling struc-
ture from which to hang your trap.
Note: Due to the variety of ceiling structures no
hardware is supplied to attach to the ceiling. Be
certain suitable lag bolts, toggle bolts, eye bolts
etc. are used which will support up to 40 lbs. each.
2. Table mounting: (fig. 3)
Simply place the trap on a table in a suitable loca-
tion near an electrical outlet.
Do not install:
Near competing light sources
Near water or other damp locations
Where traffic could possibly damage unit
Near excessive heat sources such as ovens
or furnaces
Tip
Which ever mounting method you decide to go
with you will maximize the performance by incor-
porating two main concepts.
1. Place Terminator trap 4’ to 6’ (1.2 m to 1.8 m)
above floor.
2. Preferred color of wall is white or a light color
if the Terminator unit has to be placed close
to wall.
Fig. 2
Fig. 3
72955-5-6-2014
Paraclipse ™ Terminator
Page 5
ULTRAVIOLET LAMP INSERTION
Grill Removal and Installation:
(fig. 4)
1. Removal:
Lift the grill up to a horizontal position and pull the
grill out of the mounting holes.
2. Installation:
Align the grill end rods with the two mounting
holes and push in while lowering the grill.
Lamp Protector Removal:
1. Carefully remove the cardboard from the two
lamps. Check lamps to make sure they are se-
cure in the light sockets. Discard the lamp pro-
tector cardboard. (fig. 5 and 6)
2. Reinstall grill.
Note:
It is recommended to replace the
ultraviolet lamps every eight months of use to
maintain optimum performance of the unit.
At eight months of continuous use the UV output
of the lamp have lost approximately 30% of the
effectiveness and should be replaced. After this
time the lamp may still light but is no longer
emitting enough of the special UV light frequency
required for an effective insect catch.
Replacement bulbs: part # 72917
Troubleshooting:
If the lamps will not light check the following:
Make sure unit is plugged in.
Both lamps are inserted properly and rotated
90 degrees.
72955-5-6-2012
Fig. 4
Fig. 5
Fig. 6
HG—LAMP CONTAINS MERCURY
Manage in Accordance with Disposal Laws
See: www.lamprecycle.org