OPTI-UPS OD1000 User Manual
Page 7

6.1Maintenance
z Keep the UPS in an upright position.
z Inspect on a regular basis whether screws are loose.
z It is recommended that the UPS be installed in a ventilated area. It
w i l l h e l p t o p r o l o n g t h e l i f e o f t h e b a t t e r y.
z When changing the batteries, it is recommended to use batteries that
h a v e t h e s a m e s p e c i f i c a t i o n s .
z A regular maintenance check is required when there is no power
f a i l u r e f o r a l o n g t i m e . T h e u t i l i t y i n p u t p o w e r s h o u l d b e t u r n e d o ff
p u r p o s e l y t o d i s c h a rg e t h e b a t t e r i e s ( t h e d i s c h a rg e p e r i o d d e p e n d s o n
t h e l o a d a n d t h e b a t t e r i e s ) . R e s t o r e t h e u t i l i t y i n p u t t o c h a rg e t h e
b a t t e r i e s f o r n o f e w e r t h a n 6 h o u r s e a c h t i m e . W h e n t h e t e m p e r a t u r e
i s l o w e r t h a n 3 0
, d i s c h a rg e t h e b a t t e r i e s e v e r y 3 m o n t h s ; w h e n t h e
t e m p e r a t u r e i s h i g h e r t h a n 3 0
, d i s c h a rg e e v e r y 2 m o n t h s .
6.2 Storage
z Store the unit in a dry environment.
z The temperature should be lower than 50
, a n d t h e h u m i d i t y n o t
m o r e t h a n 9 0
.
z Charge the batteries for at least 6 hours before storage to keep it full.
z Disconnect the cables connecting the UPS circuit and the battery
b e f o r e s t o r a g e .
z Batteries must be recharged after being stored for more than 3 months
a n d e v e r y t h r e e m o n t h s t h e r e a f t e r.
6.
M
AINTENANCE
7.1 Eliminating the Malfunctions
In chapter 8 there are answers to some basic problems that
may help you to trouble-shoot your UPS. Please read them
before contacting OPTI-UPS service center.
7.2 Obtaining Repair Services
Please provide the UPS model and serial number, date of
purchase and the invoice. Also describe the problems that you
have encountered on the UPS. Please ship back using the
original box.
7.3 Warranty
Wi t h i n t h e w a r r a n t y p e r i o d t h e U P S w i l l b e r e p a i r e d f r e e o f c h a rg e . T h e
d a m a g e s r e s u l t i n g f r o m l a c k o f p a c k a g i n g m a t e r i a l s i n s e n d i n g t h e U P S
b a c k f o r r e p a i r i n g a r e e x c l u d e d f r o m t h e w a r r a n t y.
A t t e n ti o n
:
T h e fo ll o wi n g a re s o m e c o nd i tio n s t ha t a re no t co v e re d u n d er
w a r r a n t y
. C h a rg e s w i l l b e a p p l i e d b y t h e f o l l o w i n g f o r m u l a . ( c h a rg i n g
s t a n d a r d
r e p a i r c h a rg e
p a r t s c h a rg e
s h i p p i n g e x p e n s e s ) :
z Handled improperly or not according to the product user manual
z Taking the UPS to a repair shop not authorized by OPTI-UPS after the
f a i l u r e o c c u r s ,
z Purposely damaging the UPS
z
F a i l u r e s d u e t o u n e x p e c t e d e v e n t s o r a c c i d e n t s ( s u c h a s f i r e , f l o o d ,
e a r t h q u a k e , l i g h t n i n g s t r i k e , g a s e x p l o s i o n , a n d w a r
13
7.
R
EPAIRING