Refrigerator owner maintenance yearly record – Dometic RM2551 User Manual
Page 21
- 21 -
refrigerator owner maintenance yearly recorD
#USTOMER .AME
-ODEL .O
$ATE
!DDRESS
3ERIAL
#ITY
:IP
0HONE
&)234
Date:
Dealership:
Address:
City:
State:
Zip:
Phone:
Technician:
Cleaned Burner Assembly: Yes / No
Cleaned/Check All Terminals Connections:
Yes / No
Cleaned/Inspect All Ground Connections:
Yes / No
Inspect and Test Door Seals:
Yes / No
Inspect and Tighten LP Lines:
Yes / No
Power Ventilator Installed: Yes / No
*Gas Safety Shutdown in 45 seconds:
Yes / No
!#45!,
30%#
Electrode Gap
3/16"
Thermister Reading
7-10,000 ohms @ 32°
*D/C Voltage
9.5 to 15 volts D/C
*A/C Voltage
120 Volts ± 10%
Thermocouple Reading
25-35 Millivolts
*Delay Between Modes
Approx. 5 seconds
* Use PAL RV Diagnostic Tool for these tests.
)#%-!+%2
Inspect Water Valve and All Connections:
Yes / No
Inspect Heat Tape Switch for Proper
Operation:
Yes / No
3%#/.$
Date:
Dealership:
Address:
City:
State:
Zip:
Phone:
Technician:
Cleaned Burner Assembly:
Yes / No
Cleaned/Check All Terminals Connections:
Yes / No
Cleaned/Inspect All Ground Connections:
Yes / No
Inspect and Test Door Seals:
Yes / No
Inspect and Tighten LP Lines:
Yes / No
Power Ventilator Installed: Yes / No
*Gas Safety Shutdown in 45 seconds:
Yes / No
!#45!,
30%#
Electrode Gap
3/16"
Thermister Reading
7-10,000 ohms @ 32°
*D/C Voltage
9.5 to 15 volts D/C
*A/C Voltage
120 Volts ± 10%
Thermocouple Reading
25-35 Millivolts
*Delay Between Modes
Approx. 5 seconds
* Use PAL RV Diagnostic Tool for these tests.
)#%-!+%2
Inspect Water Valve and All Connections:
Yes / No
Inspect Heat Tape Switch for Proper
Operation:
Yes / No