To keep the refrigerator working properly, a qualified service technician should, at least once a year,

inspect the connections, the control system, the LP gas pressure and flue baffle. The service and mainte-

nance described in this section is to be performed by service personnel only.

maintenance & service

replacing the fuses

power module
To replace the fuses, follow these steps:

Turn off the refrigerator.
unplug the power cord and disconnect the

12V wires.
Remove the power module cover.
snap the fuse out of the fuse holder.
Fit the new fuse in to the fuse holder.
Put back the power module cover.

Dm2652 (

with optional fan

), Dm2852 (

with optional fan)

,

Dm2862 (

with

optional

fan

), nDm1062 & nDr1292

inline fuse

The 3 a inline fuse for the power vent fans is connected to the

12V DC socket. To replace the inline fuse, follow these steps:

Disconnect 12V DC power.
open the fuse holder.

Replace the fuse.

Put the holder back together.

1.
2.

.
4.
5.
6.

1.
2.

.

4.

electric equipment
heater

The heat necessary for the operation of an absorption cooling

unit is supplied by an electric heater mounted in a pocket of the

boiler system.
2-way models are equipped with one electrical heater for

120 V aC.

-way models are equipped with two electrical heaters - one for

120V aC and one for 12V DC.

replacing the heater

To replace the heater, follow these steps:

Turn off the refrigerator.
unplug the power cord and disconnect the

12V DC power.
Remove the power module cover.
Disconnect the heater leads.
With a pair of pliers, unfold the lug holding the lid

of the boiler casing. open the lid.
Remove some insulation wool for the heater to be

accessible.
Turn and lift the heater out of its pocket.
Fit the new heater into the pocket.
Connect the leads and refit the power module cover.
Put back the insulation wool.
Close the lid of the boiler.

fuses

2-way models are equipped with 2 fuses - one for the refrig-

erator control system and one for the aC heater.
-way models are equipped with fuses - two fuses in the

power module and one in-line blade fuse.

Control system

3 a

aC heater

5 a

12 V DC heater

30 a

1.
2.

.
4.
5.

6.

.
8.
9.

10.
11.

CAUTION

If your refrigerator stops cooling, immediately turn the refrigerator off and see a Dometic dealer.