If the opener is working, The gate closes then opens again on its own, The gate opens then closes again on its own – Mighty Mule FM700 User Manual
Page 36
![background image](/manuals/739390/36/background.png)
32
The Gate CLOSES Then Opens Again on its Own:
1. Check the position of the mounting brackets and readjust if necessary.
2. Check the gate for binding or hinge damage.
3. Check the position of the stroke adjustment knob.
The Gate OPENS Then Closes Again on its Own:
1. Check the position of the mounting brackets and readjust if necessary.
2. Check the gate for binding or hinge damage.
3. Check the position of the stroke adjustment knob.
The GTO, Inc. Technical Service Department is open
Monday – Thursday 7:30
A.M.
– 5:30
P.M.
and Friday 8:00
A.M.
– 12:00
P.M.
(Eastern Time)
Fax (850) 575-8950 • Web site: www.gtoinc.com
E-Mail: [email protected]
Telephone (800) 543-1236
Telephone (850) 575-4144
VOLTAGE LIMITS
If the Opener is Working
18 Vac Transformer __________________________ 18.0 to 22.0 Vac
5 W Solar panel (single) _______________________ 18.0 to 22.0 Vdc 300 mA
measure voltage at panel and control box.
12 V Battery ________________________________ 12.0 to 13.5 Vdc 7.0 Ah
Charging circuit _____________________________ 12.0 to 14.8 Vdc
measure voltage with battery connected