6. PARAMETERS
To set parameter, turn on the scale.
Press
key during the self checking.
Display will be show
pn
Press
,
and
to enter, display will be show
po chk
Menu
Sub Menu
Description
P 0
chk
Set H
Set high limits for check weighing
Set L
Set low limits for check weighing
beep
NONE No beep for check weighing
Ok
Beep, when check weighing
between the limits
ng
Beep, when check weighing out of
the limits
P 1
com
Mode
This option is used to set
accumulation and RS-232
communication
Options:
Cont : data send continues
St 1 : Send data one time,
when stable.
St c : Send data continuously,
when stable
P r1 : Send data one time,
when press print
Key (in printer mode)
Pr 2 : Send data to print and
accumulation,
When press
.key
Auto : Auto accumulate and
auto print mode.
When weight stable and
return to zero.
Ask : Ask mode,
Command R: read data
Command T: Tare
Command Z: Zero
Wireles: Wireless mode
(communication
through wireless)