Check weighing – LW Measurements BWS NTEP Weighing Platform Scale 500lb User Manual
Page 12

BW/BWS Series Indicator Technical Manual
- 9 -
5.2. Check Weighing
It can set an upper or lower limit when weighing with the limits range.
During the limit controls dividing the unit will indicate whether a value
upper or lower limits with an alarm sound .
5.2.1. Set Limits
Press
and
key together, display will be show
set h.
Press
key to select
set h or set l
Press
key to confirm, display will show 00000 and will blink the last
digit.
Enter the high limit value by using
and
keys to change the
active digits and press
key to increment the value.
Press
key to confirm, display will show set l
Enter the high limit value by using
and
keys to change the
active digits and press
key to increment the value.
Press
key to confirm.
To escape from the settings press
key.
5.2.2. Set Check Weighing
Press
and
key together, display will be show
set h.
Press
key to select display
beep.
Press
key to confirm, display will be shown none or ok or ng
Check mode
none : No beep sound in the limits. Function turned off.
Check mode
ok : When the weight is between the limits. OK will shown