Utilities

Section 5

QUANTUM

49

®

QUANTUM User Manual

1.

Enter the “Utility” menu by pressing the UTILITY button once.

2.

Press NEXT PAGE button until page 8 is reached.

3.

Use the DATA WHEEL to select which setup you would like to dump.

4.

Press the DATA WHEEL to change the cursor location to the next selection.

5

Select the name of the preset you would like to dump.

6.

Press the UTILITY button to start the dump.

A/D CALIBRATE

This page of “Utilities” is a calibration section for the analog to digital converter chips. To cal-
ibrate the converters, first turn the input controls of the QUANTUM fully counter-clockwise
(-

). Calibrations performed with these controls open at all could result in inaccurate calibra-

tions, giving the QUANTUM poor processing performance. After the input controls have been
turned to the (-

) position, press the UTILITY button. If the calibration is not successful, the

following text will appear in the third parameter area: “A/D CAL FAIL!” If this happens you
should turn the QUANTUM off then back on. If the problem persists, call dbx technical support
at 1-801-568-7660 for assistance. Call after the unit is allowed to warm up to operating temper-
ature (approx. 10 minutes).

CONTRAST

The contrast selection adjusts the displays visibility.

5.10 Misc.

5.9 A/D Calibrate

5.8 Setup SYSEX Data (cont.)