Vision, User manual and installer guide, Miscellaneous commands – Lumagen Vision User Manual
Page 22

Vision
™
User Manual and Installer Guide
© 2003 Lumagen, Inc.
19
Rev 1.13
Pass-through Sync Processing
Select the pass-through sync processing mode. If processing is enabled, pass-through
sync signal polarity is processed to match internally generated sync levels. In this case,
the pass-through sync type must match the internally generated sync type. If pass-through
sync buffering is selected, the sync signals are simply buffered.
MENU
→
IN
→
ADJ
→
SYNC
→
(
PROCESS, BUFFER
),
OK
Input Name
Each input configuration memory can be named. Follow the on-screen directions. The
and arrows select which input to change and then which character to change. The
and arrows change the selected character. The command format is:
MENU
→
IN
→
NAME
Copy Input Settings
Copy the input setup (contrast, etc.) from the active memory, to the selected memory, or
memories. Since the parameters for the first input calibrated will likely be closer to
optimal than the factory defaults, this command can speed up the calibration process.
The command format is:
MENU
→
IN
→
COPY
→
(
ALL, ALLMEMA, ALLMEMB, 1A
–
8A
,
1B
–
8B
),
OK
Miscellaneous Commands
On-Screen-Display Enable
Enable or disable On-Screen-Display (OSD) activation after user commands. If enabled,
the OSD shows the selected input, input aspect ratio, and zoom.
MENU
→
MISC
→
OSD
→
(
OFF
,
ON)
,
OK
Lock the Configuration
The configuration can be locked to prevent unintended changes. When locked, the input
selection keys function normally, but setup parameters are fixed. The command format is:
MENU
→
MISC
→
LOCK
→
(
UNLOCKED
,
LOCKED)
,
OK
The following command can unlock the configuration memories without being able to
see the screen.
MENU 0 9 1 5
Same as
MENU
→
MISC
→
LOCK
→
UNLOCKED
,
OK
Initial Power State
When power is first connected to the unit, it can be set to turn on (
ON)
, or it can start in
standby mode (
STBY)
. Note,
ON
and
STBY
commands are not affected. The command
format is:
MENU
→
MISC
→
POWR
→
AUTO
→
(
ON
,
STBY)
,
OK