Page 3. settings, Status led operation, Ctap-001 – Lingenfelter L460190108 Lingenfelter CTAP-001 Clutch & Throttle Activation Position Switch v1.7 User Manual
Page 4
Page 3.
Settings:
• Controlled by three ten position switches on the front face and a
programming button inside the back cover of the CTAP-001
• Two ten position switches for selecting the activation percentage
• Percent x10
• Percent x1
• One ten position switch for selecting the activation hysteresis
• Hysteresis values of 0%, 0.5%, 1%, 1.5%, 2%, 2.5%, 3%, 3.5%,
4%, and 4.5%
• Hysteresis example: If the activation percentage switches are set to
90% and the hysteresis switch is set to 4%, the CTAP should switch
the outputs when the signal reaches 90% of the pedal/throttle travel
and then switch back when the signal falls below 86% of the pedal/
throttle travel.
• It is recommended to use at least a small percentage of hysteresis
as it is possible for the CTAP to continually switch the outputs
on and off if the pedal/throttle position is held at the user-defined
activation percentage point with no hysteresis.
• When all three switches are set to zero, the CTAP-001 is in programming mode.
• One programming button inside the rear cover of the CTAP-001
• While in programming mode, press this button to calibrate the input signal voltages.
Status LED Operation:
• Blinking GREEN when CTAP-001 is in programming mode (all three switches are set to zero)
• Blinking GREEN+RED after the programming button has been pressed and the CTAP-001 is observing the analog
input voltages. The LED will continue blinking GREEN+RED until two sweeps (from closed throttle/released clutch to
Wide Open Throttle/depressed clutch) of at least 1.5 volts are taken. Once this parameter is met, the LED will change
to one of the following colors:
• In programming mode, a solid GREEN LED signifies that the programming of the analog voltage range was
successful.
• Blinking RED when an error occurs, which can be fixed by reprogramming the module. The following conditions
must be met for the programming to be successful:
• The span between the closed throttle/released clutch signal and the Wide Open Throttle (WOT)/depressed
clutch voltages must be at least 1.5 volts.
• The difference between the first WOT/depressed signal voltage and the second WOT/depressed signal
voltage must be less than or equal to 0.1 volts.
• Solid GREEN LED when the CTAP-001 is powered up in normal operating mode and remains solid GREEN until the
input exceeds the user-defined percentage set point.
• Solid RED once the user-defined percentage set point has been exceeded, which means that the outputs are active--
remains solid RED until the input falls below the user-defined set point (and hysteresis, if set to some percentage
besides zero)
Power - Status
CTAP-001
Clutch/Throttle Activation
Ground - Black
Output Normally On - Gray
Output Normally Off - Yellow
Position Switch
Percent x10
Percent x1
+12V Switched Power - Red
Activation Percentage
Analog Signal In - Purple
+12V Output, Norm Off - Orange
Hysteresis
0 .5
1
1.
5
2
2.5
3
3.
5
4
4.5