Lamar Technologies CA 1550 User Manual
Page 12

12
DIMENSIONS: 20 ½ L x 16 ¾ W x 8 ½ D
WT 67 LBS
*Actual Current and Voltage, charge and discharge, start at zero, but Digital Meters
may not read to zero.
VI.
CHANGING THE AC LINE INPUT FROM 115 TO 230 VOLTS.
WARNING:
Before change-over, the AC line plug must be physically
unplugged from any wall outlet or switch box or serious injury or death may
result from AC line electrical shock.
a.
Unless otherwise specified 4159 is shipped connected
in the 115 Volt AC position and a standard USA 125
Volt 15 ampere 3 wire grounded plug is connected to
the AC line cord.
b.
To change the AC line input from 115 Volt to 230
Volt perform the following:
1.
Remove the large louvered panel on the
power section of the unit. Wired to the large
main transformer is the terminal strip with
two jumpers. The diagram below denotes the
jumper arrangement for AC line input of 115
or 230 Volts. The user will have to adapt or
change the AC plug to conform to the AC
line mains receptacle. For 230 Volt operation
the two jumpers may be placed together on
the 2 and 3 terminals so that the second
jumper is not lost if change over back to 115
Volts is required in the future.