Konig Electronic Gas detector User Manual
Page 3

ENGLISH
3
Where not to install the gas detector
• In a small enclosed space
• Directly above a sink
• Next to a door or window
• Next to an extractor fan
• In an area where the temperature may drop below -10°C or exceed 40°C
• Where dirt and dust may block the sensor
• In a damp or humid location
Operation
Display gas level
indicator
Gas sensor
Alarm buzzer
Alarm indicator
State indicator
Power indicator
1. Connect the gas detector to a power outlet. The green power indicator is
constantly on, and it alarms with beep sound (red alarm indicator flashes
twice). The display gas level indicator displays “-” for about 4 minutes. Then
the gas detector starts the alarm detection mode.
2. When the concentration is 0, 1 or 2 the status indicator is off.
3. When the concentration is 3, the status indicator is red and the alarm
indicator flashes. When the concentration is 3, 4 or 5, it alarms with a slow
beep tone.
4. When the concentration is 6, 7, 8 or 9 it alarms with a fast beep tone.
5. When the display gas level indicator concentration is A, it alarms with the
status indicator in red, alarm indicator constantly on in red.