Heath Consultants Aqua-Scop User Manual
Page 15
Figure 7 illustrates the Meter Readout Module, an accessory item with
AQUA-SCOPE® . The charger plug/jack system differs from the plugs
and jacks used with other AQUA-SCOPE® components to minimize
error. A rechargeable nine-volt battery, internal to the Meter Readout
Module, powers the instrument.
BATTERY TEST: The internal battery may be tested by depressing the
square button “Battery Test” switch shown in Figure 7 while observing
the Meter (the instrument must be turned “ON”). The Meter must read a
minimum of 0.7. If a lower reading is obtained, a complete recharge is
required.
F.
Resonant Plate (part No. 2921326).
(Figure8)
1.
General Specifications:
CONSTRUCTION:
1/8” steel, octagonal plate.
Approximately 6 1/2” diameter
maximum.
WEIGHT:
Approximately 2.5 Lbs. (1135 Grams).
The Resonant Plate shown upside down with the contact rod and thumbscrews
not assembled in Figure 8 is used to enhance water leak detection in unpaved
areas. The Ground Microphone rests on top of the Plate during use.
12