Hatteland Display 19 inch - JH 19T14 MMC User Manual
Page 9
9
Serial Communication (SCOM) Interface
Communication Interface
IND100084-12
CMD
Message Commands and Queries (CMD) Contents
The command can be one of the following values and consists always of 3 bytes in positions 2,3,4:
Byte 2 Byte 3 Byte 4 ASCII Description
I/O Unit Type Page
0x42
0x52
0x54
"BRT" User Brightness Control
W
all
11
0x42
0x5A
0x5A
"BZZ"
Buzzer Control
W
all
11
0x45
0x54
0x43
"ETC" Elapsed Time Counter Query
R
all
12
0x44
0x4C
0x4E
"DLN" Query available ECDIS packages
R
xxD
12
0x44
0x4C
0x3F
"DL?"
Download ECDIS package table x
R
xxD
13
0x44
0x53
0x54
“DST” Display State
W
xxD
13
0x4D
0x41
0x4E
“MAN” Manufacturer ID Code
R
xxD
14
0x50
0x4F
0x54
"POT" Potentiometer Control
W
all
14
0x53
0x4E
0x42
"SNB" Serial Number Query
R
all
15
0x53
0x57
0x49
"SWI"
ECOM Software Version ID Query
R
all
15
0x53
0x57
0x4B
"SWK" Keypad Software Version Query
R
all
15
0x54
0x4D
0x50
"TMP" Temperature Sensor Query
R
xxD
16
0x54
0x59
0x50
"TYP" Type/Model Number Query
R
all
16
0x56
0x45
0x52
"VER" Unit ID Model/Version Number
R
all
17
0x4D
0x43
0x43
"MCC" OSD Control Functionality (*1)
with key global commands:
"?" = Query OSD value
"R" = Reset OSD value
"r" = Reset OSD value
"+" = Increase OSD value
"-" = Decrease OSD value
R/W
xxD
18
Notes:
I/O
= R=Read, W=Write.
Unit Type
= xxD = MMD/STD, xxC = MMC units, all = MMD/STD/MMC
Page #
= Page number in this manual where command is detailed.
(*1) “MCC"
= command is not supported on Maritime Multi Computer (MMC) units, due to no OSD menu
available. The “MCC” command also features a Query “?” mode, “R” or “r” reset mode to factory
default, increase +1 from current value “+” and decrease -1 from current value “-”. Details and
usage of these commands are available later in this manual.
(*2) "DL?/DLN" = Command not available on units manufactured before May 2009.