Hatteland Display 19 inch - JH 19T14 MMC User Manual
Page 22
22
Serial Communication (SCOM) Interface
Communication Interface
IND100084-12
MCC Command
Syntax and Functionality
ACK Details and Values
PIP Horizontal Position
Note:
Not available on STD units.
Syntax : 07 FF 4D 43 43 04 22
A4
ww xx yy
zz
Function Examples:
Example "050": 07 FF 4D 43 43 04 22
A4
30 35 30
C6
Query "?" : 07 FF 4D 43 43 02 24
A4
3F
1C
Reset "R" : 07 FF 4D 43 43 02 24
A4
52
09
Reset "r" : 07 FF 4D 43 43 02 24
A4
72
E9
Increase "+" : 07 FF 4D 43 43 02 24
A4
2B
30
Decrease "-" : 07 FF 4D 43 43 02 24
A4
2D
2E
Where
ww
= "0" to "0"
Where
xx
= "0" to "6"
Where
yy
= "0" to "F"
Where
zz
= Calculated Checksum
Max Range:
"0" "0" "0" to "0" "6" "4"
Default: "0" "0" "0"
PIP Vertical Position
Note:
Not available on STD units.
Syntax : 07 FF 4D 43 43 04 22
A5
ww xx yy
zz
Function Examples:
Example "050": 07 FF 4D 43 43 04 22
A5
30 35 30
C5
Query "?" : 07 FF 4D 43 43 02 24
A5
3F
1B
Reset "R" : 07 FF 4D 43 43 02 24
A5
52
08
Reset "r" : 07 FF 4D 43 43 02 24
A5
72
E8
Increase "+" : 07 FF 4D 43 43 02 24
A5
2B
2F
Decrease "-" : 07 FF 4D 43 43 02 24
A5
2D
2D
Where
ww
= "0" to "0"
Where
xx
= "0" to "6"
Where
yy
= "0" to "F"
Where
zz
= Calculated Checksum
Max Range:
"0" "0" "0" to "0" "6" "4"
Default: "0" "0" "0"
PIP Window Size Select
Note:
Not available on STD units.
Syntax : 07 FF 4D 43 43 03 23
A6
xx yy
zz
Function Examples:
Example "09" : 07 FF 4D 43 43 03 23
A6
30 39
F0
Query "?" : 07 FF 4D 43 43 02 24
A6
3F
1A
Reset "R" : 07 FF 4D 43 43 02 24
A6
52
07
Reset "r" : 07 FF 4D 43 43 02 24
A6
72
E7
Increase "+" : 07 FF 4D 43 43 02 24
A6
2B
2E
Decrease "-" : 07 FF 4D 43 43 02 24
A6
2D
2C
Where
xx
= "0" to "0"
Where
xx
= "0" to "A"
Where
zz
= Calculated Checksum
Max Range: "0" "0" to "0" "A"
Default: "0" "0"
Second Source Select
Note:
Not available on STD units.
Syntax : 07 FF 4D 43 43 03 23
A7
xx yy
zz
Function Examples:
Example "B3" : 07 FF 4D 43 43 03 23
A7
42 33
E3
Query "?" : 07 FF 4D 43 43 02 24
A7
3F
19
Reset "R" : 07 FF 4D 43 43 02 24
A7
52
06
Reset "r" : 07 FF 4D 43 43 02 24
A7
72
E6
Increase "+" : 07 FF 4D 43 43 02 24
A7
2B
2D
Decrease "-" : 07 FF 4D 43 43 02 24
A7
2D
2B
Where
xx
= "A" to "F"
Where
yy
= "1" to "3"
Where
zz
= Calculated Checksum
Available functions:
"A1" = Analog RGB1 (default)
"A2" = Analog RGB2
"B1" = Composite1
"B2" = Composite2
"B3" = Composite3
"C1" = S-Video1
"C2" = S-Video2
"C3" = S-Video3
"F1" = DVI
Color Temperature Select
Syntax : 07 FF 4D 43 43 02 24
B3
xx
zz
Function Examples:
Example "2" : 07 FF 4D 43 43 02 24
B3
32
1A
Query "?" : 07 FF 4D 43 43 02 24
B3
3F
0D
Reset "R" : 07 FF 4D 43 43 02 24
B3
52
FA
Reset "r" : 07 FF 4D 43 43 02 24
B3
72
DA
Where
xx
= "0" to "3"
Where
zz
= Calculated Checksum
Available functions:
"0" = 9500K
"1" = 8000K (default)
"2" = 6500K
"3" = 5000K
"4" = USER
Examples on Response:
"8" "0" "0" "0" (8000k)
"U" "S" "E" "R" (USER)
Red Level for Selected Color
Temperature
Syntax : 07 FF 4D 43 43 03 23
B4
xx yy
zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23
B4
35 30
E6
Query "?" : 07 FF 4D 43 43 02 24
B4
3F
0C
Reset "R" : 07 FF 4D 43 43 02 24
B4
52
F9
Reset "r" : 07 FF 4D 43 43 02 24
B4
72
D9
Increase "+" : 07 FF 4D 43 43 02 24
B4
2B
20
Decrease "-" : 07 FF 4D 43 43 02 24
B4
2D
1E
Where
xx
= "0" to "6"
Where
yy
= "0" to "F"
Where
zz
= Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "3" "2"