Query osd command), R” / “r” (reset osd command), Increase osd command) – Hatteland Display 19 inch - JH 19T14 MMC User Manual
Page 25: Decrease osd command)
25
Serial Communication (SCOM) Interface
Communication Interface
IND100084-12
MCC Command
Syntax and Functionality
ACK Details and Values
PIP Window Transperancy
Syntax : 07 FF 4D 43 43 03 23
ED
xx yy
zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23
ED
35 30
AD
Query "?" : 07 FF 4D 43 43 02 24
ED
3F
D3
Reset "R" : 07 FF 4D 43 43 02 24
ED
52
C0
Reset "r" : 07 FF 4D 43 43 02 24
ED
72
A0
Increase "+" : 07 FF 4D 43 43 02 24
ED
2B
E7
Decrease "-" : 07 FF 4D 43 43 02 24
ED
2D
E5
Where
xx
= "0" to "6"
Where
yy
= "0" to "F"
Where
zz
= Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "6" "4"
Custom Input Timing
Syntax : 07 FF 4D 43 43 02 24
EE
xx
zz
Function Examples:
Example "5" : 07 FF 4D 43 43 02 24
EE
35
DC
Query "?" : 07 FF 4D 43 43 02 24
EE
3F
D2
Reset "R" : 07 FF 4D 43 43 02 24
EE
52
BF
Reset "r" : 07 FF 4D 43 43 02 24
EE
72
9F
Where
xx
= "0" to "7"
Where
zz
= Calculated Checksum
Available functions:
"0" - Mode 1066 x 800i
"1" - Mode 1056 x 792i
"2" - Mode 1296 x 972i
"3" - Mode 1280 x 1024i
"4" - Mode 1365 x 1024i
"5" - Mode 1270 x 996
"6" - Mode 10280 x 1024
Menu Button
Send Only : 07 FF 4D 43 43 01 25
F7
08
Physical Button press equivalent
Select-Down Button
Send Only : 07 FF 4D 43 43 01 25
FA
05
Physical Button press equivalent
Select-Up Button
Send Only : 07 FF 4D 43 43 01 25
FB
04
Physical Button press equivalent
Right / + Button
Send Only : 07 FF 4D 43 43 01 25
FC
03
Physical Button press equivalent
Left / - Button
Send Only : 07 FF 4D 43 43 01 25
FD
02
Physical Button press equivalent
“?” (Query OSD Command)
This command can be used to query the unit for the chosen command and it’s current operating value. Note that this
feature is only available when using the Unit OSD Control “MCC” command. This command is a read-only command
which will not change the current value.
“R” / “r” (Reset OSD Command)
This command can be used to reset the unit for the chosen command and it’s current operating value. Note that this
feature is only available when using the Unit OSD Control “MCC” command. When this command is sent the current
value will be reset back to the original factory default value. The factory default value will vary depending on the
command and/or with customized units. Both “R” (0x52) and “r” (0x72) can be used to execute the reset command.
“+” (Increase OSD Command)
This command can be used to increase from the current value of the chosen function and add 1 step or 1 in value to this
parameter. Note that this feature is only available when using the Unit OSD Control “MCC” command. This command
is a write command which will change the current value.
“-” (Decrease OSD Command)
This command can be used to decrease from the current value of the chosen function and substract 1 step or 1 in value
to this parameter. Note that this feature is only available when using the Unit OSD Control “MCC” command. This
command is a write command which will change the current value.