beautypg.com

22 serial/ethernet communication (scom) interface – Hatteland Display 26 inch - HD 26T21 MMC (Widescreen) User Manual

Page 22

background image

22

Serial/Ethernet Communication (SCOM) Interface

IND100084-14

"TYP" - Type/Model Number Query

This query is sent to the unit in order to identify the unit type by its model number / part number. No data shall be sent

with this query.

The unit will reply to this command with an ACK attention code. The DATA field should be translated to an ASCII text

string which indicate the specified Type/Model Number, e.g: "HD17T21MMCMJDOABA".

FYI: Which translates to "HD 17T21 MMC" (http://www.hatteland-display.com/panel_computer_hd17t21mmc.php) with

a configuration added to it by using the letters "-MJD-OABA". The meaning of "-MJD-OABA" can only be found in the

description field of invoice documents and service documents. In this example the exact description for the unit is:

"17.0" MMC IntelQM57 CEL 1.86GHz 2GBRAM 250GBHDD OSNone ACDC Bonded Black GDC Buzzer"

Example:

Command to retrieve Type/Model Number

0x07

0xFF

0x54

0x59

0x50

0x00

0xFC

Acknowledge Type/Model Number "HD17T21MMCMJDOABA":

0x06

0xFF

0x54

0x59

0x50

0x11

0xEC

0x48

0x44

0x31

0x37

0x54

0x32

0x31

0x4D

0x4D

0x43

0x4D

0x4A

0x44

0x4F

0x41

0x42

0x41

0x89

"QDU" - QM57 Chipset Duplex Mode

This command sets the half or full duplex mode for the external physical RS-422 / RS-485 port on a MMC unit.

0x00

Half Duplex Mode

0xFF

Full Duplex Mode