Sub-function: 0x22 watchdog monitor count reset, Sub-function: 0x24 alarm reset, Sub-function: 0x25 alarm fault test – Hatteland Display 13 inch - HD 13T21 STD (Widescreen) User Manual
Page 17: Sub-function: 0x26 alarm sound off

sssssss
DOC101681-1- rev.2
17
8 and 13" DIS DDC Control
All intellectual properties belongs to Hatteland Display AS
This command is watchdog active to wait time.
Command example:
[S] 6E [W] 51 86 E7 F3
02
21
01 F4
7B [P]
[S] 6E [W] 51 84 E2 F3
02
21
89 [P]
[S] 6F [R] 6E 85 E4
02
21
01 F4
89 [P]]
Red color Set or Get data length.
Green color Sub function ID.
Blue color Set or get data.
3.3.9. Sub-Function: 0x22 Watchdog Monitor Count Reset
This command is reload wait time value to watchdog count register.
Command example:
[S] 6E [W] 51 84 E7 F3
00
22
8D [P]
Red color set data length.
Green color Sub function ID.
3.3.10. Sub-Function: 0x24 ALARM Reset
This command is initially to watchdog board status.
Command example:
[S] 6E [W] 51 84 E7 F3
00
24
8B [P]
Red color set data length.
Green color Sub function ID.
3.3.11. Sub-Function: 0x25 ALARM Fault Test
This command is fault status test.
Command example:
[S] 6E [W] 51 84 E7 F3
00
25
8A [P]
Red color set data length.
Green color Sub function ID.
3.3.12. Sub-Function: 0x26 ALARM Sound OFF
This command is buzzer OFF when buzzer is active.