beautypg.com

Sub-function: 0x22 watchdog monitor count reset, Sub-function: 0x24 alarm reset, Sub-function: 0x25 alarm fault test – Hatteland Display 13 inch - HD 13T21 STD (Widescreen) User Manual

Page 17: Sub-function: 0x26 alarm sound off

background image

sssssss

DOC101681-1- rev.2

17

8 and 13" DIS DDC Control

All intellectual properties belongs to Hatteland Display AS

This command is watchdog active to wait time.

Command example:

[S] 6E [W] 51 86 E7 F3

02

21

01 F4

7B [P]



[S] 6E [W] 51 84 E2 F3

02

21

89 [P]



[S] 6F [R] 6E 85 E4

02

21

01 F4

89 [P]]


Red color
Set or Get data length.
Green color
Sub function ID.
Blue color
Set or get data.

3.3.9. Sub-Function: 0x22 Watchdog Monitor Count Reset


This command is reload wait time value to watchdog count register.

Command example:

[S] 6E [W] 51 84 E7 F3

00

22

8D [P]


Red color
set data length.
Green color
Sub function ID.

3.3.10. Sub-Function: 0x24 ALARM Reset


This command is initially to watchdog board status.

Command example:

[S] 6E [W] 51 84 E7 F3

00

24

8B [P]


Red color
set data length.
Green color
Sub function ID.

3.3.11. Sub-Function: 0x25 ALARM Fault Test


This command is fault status test.

Command example:

[S] 6E [W] 51 84 E7 F3

00

25

8A [P]


Red color
set data length.
Green color
Sub function ID.

3.3.12. Sub-Function: 0x26 ALARM Sound OFF


This command is buzzer OFF when buzzer is active.