Technical data – Hase Lima User Manual
Page 37

37
11. Technical Data
The Lima B.11, certified in compliance with DIN-EN 13240 : 2005-10/1 : 2008-06
and Art. 15 a B-VG (Austria), can only be operated when the fire box is closed; more
than one device can be connected to the chimney. VKF-No.: 22674;
The following data applies to the chimney characteristics in accordance with EN
13384-1 / 2
Combustion Values
Wood
Briquette
Nominal Thermal Output
6
6
kW
CO content at 13% O2
80
79
mg/m³
Efficiency
13
26
%
CO content at 13% O2
1104
882
mg/m³
Waste Gas Mass Flow Rate
5,5
5,5
g/s
Waste Gas Outlet Temp.
320
320
˚C
Min. Supply Pressure at Nominal Thermal Output
12
12
Pa
Depending on the insulation of the building, the nominal thermal output of 6 kW indi-
cated on 20 - 80 m² (subject to change).
Dimensions:
Height
Width
Depth
Stove
121 cm
48 cm
48 cm
Fire box
43 cm
28 cm
30 cm
Weight (ceramic / soapstone):
178/214 kg
Flue pipe diameter:
15 cm
Pipe diameter of Hase ventilation system*
10 cm
* For separate air supply in low-energy houses and insufficient combustion air supply
in the room where the stove is installed
Front view
Side view
Top view
Dimensions in cm
Connection area for the
inst. of Hase air system
below
Stove‘s angle of rotation:
180° · Can be stopped in
place and locked right/left in
15° gradients. Observe safety
distances to combustible or
flammable materials!
Stove height: 121
Height for top installation: 113
24
Ш 35
6,5
Ш 48
Height for the inst. of Hase air
system: 9