Technical data delhi 114 – Hase Delhi User Manual
Page 45
![background image](/manuals/737759/45/background.png)
45
min. 20*
23
Ш 25
7
Ш 45
Ш 39
10. Technical Data Delhi 114
The Delhi 114, certified in compliance with DIN-EN 13240 and Art. 15 a B-VG (Aus-
tria), can only be operated when the fire box is closed; more than one device can be
connected to the chimney.
VKF-No.: 23311
The following data applies to the chimney characteristics in accordance with EN
13384-1 /-2
Combustion Values
Wood
Nominal Thermal Output
5
kW
Efficiency
82
%
Particulate
16
mg/m³
CO content at 13% O2
1021
mg/m³
Waste Gas Mass Flow Rate
4,5
g/s
Waste Gas Outlet Temp.
315
˚C
Min. Supply Pressure at Nominal Thermal Output
12
Pa
Depending on the insulation of the building, the nominal thermal output of 5 kW indi-
cated on 15 - 60 m² (subject to change).
Dimensions:
Height Width Depth
Stove
113,5 cm
45 cm
45 cm
Fire box
44 cm
29 cm
28 cm
Weight
118 kg
* Vertical flue pipe length
min. 20 cm
Flue pipe diameter
15 cm
Pipe diameter of Hase ventilation system**
10 cm
* For separate air supply in low-energy houses and insufficient combustion air supply
in the room where the stove is installed
Front view
Side view
Top view
Dimensions in cm
Height for top installation: 112
Stove
height:
113,5
Connection area for the
inst. of Hase air system
below
Height for the inst. of Hase air system: 18