Troubleshooting your dyson – DYSON DC07 User Manual
Page 18
Troubleshooting your Dyson
Problem
Potential solution
Less than normal or no pickup
• If vacuuming non-delicate carpeting, ensure brush control is
from cleanerhead or
set on carpets mode. Note: brushbar will only spin when the
handle is reclined.
Machine turns off in use
• Remove and check washable filter to see if it is clean (filter
should be blue in color). Wash filter if necessary as shown
on page 8.
• If you removed the soleplate, it must be refitted flush with the
cleanerhead. If it is not, refit soleplate as shown on page 15
and re-check performance.
• Be sure the filter housing, U-bend, and airway inspection valve
are snapped in securely and confirm there are no blockages.
Less than normal or no suction
• Confirm the U-bend is in place and that there are no blockages.
from wand or hose
• Remove the wand and check for blockages.
• Confirm the hose has no blockages or holes by stretching it out.
• Be sure the filter housing and airway inspection valve are
snapped in securely and confirm there are no blockages.
• Remove and check washable filter to see if it is clean (filter
should be blue in color). Wash filter if necessary as shown
on page 8.
Brushbar not spinning
• Ensure brush control is set on carpets mode.
Note: brushbar will only spin when the handle is reclined.
Loud ‘ratcheting’ noise coming
• Ratcheting may indicate there is an obstruction in the brushbar
from cleanerhead when
and is meant to protect the belt in the machine. Note: the
vacuuming
ratcheting may also occur if your carpet is not adequately
attached to the floor or if your rug has loose tassels. (This noise
does not hurt the machine.)
• Check to see if there is an obstruction in the brushbar as shown
on page 15.
• Note: when refitting the soleplate it must be fitted securely.
Affix as shown on page 15.
• If there is no obstruction, you may want to set brush control
to bare floors mode.
Unit will not stand upright
• Stand behind the vacuum holding the handle at a 45
degree angle.
• Locate and remove the airway inspection valve and take note
of the square plastic molding where the airway inspection valve
plugs into. (It should slide up and down.)
• Snap that square plastic piece up toward the ceiling.
• After it snaps into place, the unit will stand upright.
Refer to page 3 for an illustration of DC07. If this does not help with your problems, please call the
Dyson Helpline at 1-866-693-9766. The Helpline is open 7 days a week to answer your questions.
Dyson Helpline contact us at
1-866-693-9766
7 days a week
18
16852_DCO7_OP_MAN_US.qxd 5/7/07 14:00 Page 18
(Cyan plate)
(Yellow plate)
(Black plate)
(PANTONE Red 032 C plate)
10:39:28 2007-07-06 C_16852_DCO7_OP_MAN_US_4c1s.pdf