Dear Customer,

Thank you for choosing a Hanna Product.

Please read this instruction manual carefully
before using the instrument.

This manual will provide you with the necessary
information for a correct use of the instrument,
as well as a precise idea of its versatility.

If you need more technical information, do not
hesitate to e-mail us at [email protected]

This meter is in compliance with

directives.

Preliminary Examination ............................. 3

General Description ..................................... 3

Functional Description - Probe .................... 4

Functional Description - Meter ..................... 5

Specifications ............................................. 6

Probe Preparation ....................................... 7

Calibration ................................................... 8

Measurement ............................................ 10

Altitude Compensation .............................. 12

Salinity Compensation .............................. 13

Probe & Membrane Maintenance .............. 14

Battery Replacement ................................ 16

Accessories .............................................. 17

Warranty ................................................... 18

CE Declaration of Conformity .................... 19

PRELIMINARY EXAMINATION

Remove the instrument from the packing material
and examine it to make sure that no damage
has occurred during shipping. If there is any
damage, notify your Dealer.
The meter is supplied complete with:

HI 76407/4F DO probe with 4 m cable and
protective sleeve for HI9146-04

HI 76407/10F DO probe with 10 m cable &
protective sleeve for HI9146-10

2 membranes (HI 76407A) with O-rings

protective cap

30 mL electrolyte solution (HI 7041S)

4 x 1.5V AA batteries

instruction manual

rugged carrying case

Note: Save all packing material until you are

sure that the instrument functions
correctly. Any defective items must be
returned in the original packing with the
supplied accessories.

GENERAL DESCRIPTION

The Hanna HI 9146 is a water-resistant,
microprocessor-based, auto-calibrating
Dissolved Oxygen meter with ATC. It has been
developed for dissolved oxygen and temperature
measurement in water and wastewater as well
as other applications such as fish farming.
Dissolved oxygen is indicated in hundredths of
parts per million (ppm=mg/L) or in % of
saturation .
The temperature range is indicated in centigrade
from 0 to 50°C with 0.1°C resolution.
The ppm and the % saturation are both
compensated for changes in solubility of oxygen
in water and for permeability of the membrane
as well as the temperature effect.