If the batteries become weak, the meter will
display a "V" on the LCD to warn the user that
only a few hours of working life are left.
HI 9210N is also supplied with BEPS (Battery Error Prevention System),
that automatically shuts the meter off when the battery level is too low to
ensure reliable readings.
Battery replacement must only take place in a non hazardous area and
using the battery types specified in this instruction manual.
To replace the batteries, remove the rear cover of
the instrument and replace all four 1.5V AA
batteries with new ones, while paying attention
to the correct polarity. Replace the cover and
tighten the screws.
The meter is reset every time the batteries are
removed. In case of any functional problems, the
meter can be reset by removing and reinstalling
the batteries.

V

BATTERY REPLACEMENT

IMPORTANT: After performing any of the cleaning procedures, rinse the
electrode thoroughly with distilled water and soak it in HI 70300 storage
solution for at least 1 hour before taking measurements.
TROUBLESHOOTING
Evaluate your electrode performance based on the following.
• Noise (Readings fluctuate up and down) could be due to clogged/

dirty junction: Refer to the Cleaning Procedure above.

• Dry membrane/junction: Soak in HI 70300 storage solution for at

least one hour.

• Drifting: Soak the electrode tip in warm (approx. 50-60°C) HI 7082

solution for one hour and rinse the tip with distilled water.

• Low slope: Refer to the cleaning procedure above.
• No slope: Check the electrode for cracks in glass stem or bulb and

replace the electrode.

• Slow response/excessive drift: Soak the tip in HI 7061 solution for

30 minutes, rinse thoroughly in distilled water and then follow the
Cleaning Procedure above.

HI 1217D

Amplified, gel filled pH electrode with built-in temperature
sensor, DIN connector and 1 m (3.3’) cable

HI 70004P

pH 4.01 buffer solution, 20 mL sachet, 25 pcs

HI 70007P

pH 7.01 buffer solution, 20 mL sachet, 25 pcs

HI 70010P

pH 10.01 buffer solution, 20 mL sachet, 25 pcs

HI 7004L

pH 4.01 buffer solution, 500 mL bottle

HI 7006L

pH 6.86 buffer solution, 500 mL bottle

HI 7007L

pH 7.01 buffer solution, 500 mL bottle

HI 7009L

pH 9.18 buffer solution, 500 mL bottle

HI 7010L

pH 10.01 buffer solution, 500 mL bottle

HI 8004L

pH 4.01 buffer solution, 500 mL FDA bottle

HI 8006L

pH 6.86 buffer solution, 500 mL FDA bottle

HI 8007L

pH 7.01 buffer solution, 500 mL FDA bottle

HI 8009L

pH 9.18 buffer solution, 500 mL FDA bottle

HI 8010L

pH 10.01 buffer solution, 500 mL FDA bottle

HI 70300L

Storage solution, 500 mL bottle

HI 70000P

Electrode rinse solution, 20 mL sachet, 25 pcs

HI 7061L

General cleaning solution, 500 mL bottle

HI 7073L

Protein cleaning solution, 500 mL bottle

HI 7074L

Inorganic cleaning solution, 500 mL bottle

HI 7077L

Oil & Fat cleaning solution, 500 mL bottle

HI 80300L

Storage solution, 500 mL FDA bottle

HI 8061L

General cleaning solution, 500 mL FDA bottle

HI 8073L

Protein cleaning solution, 500 mL FDA bottle

HI 8077L

Oil & Fat cleaning solution, 500 mL FDA bottle

HI 721317

Rugged carrying case

HI 76405

Electrode holder

ACCESSORIES