3.1 RS232 Operation

The unit operates at 9600 baud, No Parity, 8 Data Bits and 1 Stop Bit

When IR is used, the commands response is transmitted out the RS232 port.

The following commands are available:

COMMAND

Syntax

Function

?

Prints List of commands

PWn

n=0 means POWER OFF
n=1 means POWER ON

Turn unit on or off

PW

Response= PWn as described above

Query Power Status

FR

Firmware Reset to default
Boost OFF
Output 1 to Input 1

FB

Firmware Boot & Power On

BOn

n=0 means BOOST OFF
n=1 means BOOST ON

Boost signal to correct for losses
due to cable length

BO

Response=BOn as described above

Boost Status Query

COn,m

n = output #, m = input #
n=1 (Always a 1 for the SW-HDMI-4)
m=0 thru 4 where:
m=0 means blank
m=1 to 4 means select that INPUT

Connect Output to Input

CO1

Response=CO1 as described above

Connection Status Query

ST Responds

with

POwer, BOost and COnnection status

query information as described above

Status Query

IR Sensor

Source Selection Button

Selection Indicators

Power Button

POWER

INPUT

VIDEO

INPUTS

VIDEO

OUTPUT

RS232 Serial

Control Port