beautypg.com

Configuration & operation, 2 cable requirements – Hall Research UV8-S User Manual

Page 7

background image

4 or 8 Channel Splitter PC Video & Power over Twisted-Pair Sender

5

2.2 Cable Requirements

All units can use with CAT5/5e/6 or Zero-Skew™ UTP or STP (unshielded or
shielded twisted pair) cables. Low-skew UTP cable (such as Hall Research’s Zero-
skew™ CAT5 cable) is recommended particularly if cable lengths are 200 feet or
longer.

IMPORTANT

Do not connect this unit to any LAN device such as network cards or hubs as this may cause
damage. Use EIA/TIA 568B standard straight-through patch wiring as shown below. Do not use
crossover cables.

EIA/TIA 568B WIRING STANDARD

PIN

Wire Color

1

White w/ Orange Stripe

2 Orange
3

White w/Green Stripe

4 Blue
5

White w/Blue Stripe

6 Green
7

White w/Brown Stripe

8 Brown

3. Configuration & Operation

The table below lists the recommended maximum distances from sender to the
receiver depending on the resolution used.

Refresh Rate

60 Hz

75 Hz

800x600

500 ft

500 ft

1024x768

500 ft

500 ft

1280x1024

500 ft

500 ft

Resolution

1920x1200

500 ft

500 ft

There are no user adjustments on the UV4-S or UV8-S.

Use the included screwdriver to adjust the compensation pots on the Model UV1-R
receiver for the best picture quality.

Table 1 -

Recommended
maximum CATx cable
length from sender to
the receiver

Figure 2