5.0 Troubleshooting
No Sync or Color Distortion
Most common problem can be attributed to incorrect cable connection to
the unit. The Component video and RGB signals have 3 components each.
This means that each port has 3 connections and their proper usage is
imperative. In general use the following guidelines:
G or Y Æ green cable
B or Pb Æ blue cable
R or Pr Æ red cable
5.1 Contacting Hall Research and Shipping/Packaging
Contact HRT Support at 714-641-6607 or via email or web. Before you do,
make a record of the history of the problem. We will be able to provide more
efficient and accurate assistance if you have a complete description. If you need
to ship your converter for repair, make sure to get a Return Material
Authorization (RMA) number first.
6.0 Specifications
Standards
Analog Component Video YPbPr or YCbCr and RGB signals
with sync-on-green.
Resolutions
All Standard TV, HDTV and PC resolutions Including: 640 X
480, 720 X 480, 720 X 576, 800 X 600, 1024 X 768, 1280 X
720, 1280 X 768, 1280 X 1024, 1600 X 1200, 1920 X 1080
Temperature Operating: 32 to 122°F (0 to 50°C);
Storage: –40 to +185°F (–40 to +85°C)
Enclosure Steel
MTBF
90,000 hours (calculated estimate)
Power
From utility-power (mains) outlet, through included external
power supply. Output Voltage: 6v DC Center-Positive.
Average Power Consumption: 1 Watt
Size (hxwxd) 1.38”H X 8.38”W X 3.00”D
Weight 1.2
lbs