beautypg.com

Scanner operation, Audible indicators – GoDEX GS220 User Manual

Page 8

background image

4

Scanner Operation

Audible Indicators

When the scanner is operational, the scanner provides audible feedback to

indicate the status of the scanner and the last scan. Eight settings are available

for the tone of the beep (normal, six alternate tones and no tone).

One Beep – On Power Up

When the unit powers up, the green LED turns on, then the red LED flashes and

the scanner beeps once. The red LED will remain on for the duration of the

beep. The scanner is now ready to scan.

One Beep – During Operation

When the scanner successfully reads a bar code, the red LED will flash and the

scanner beeps once (if programmed to do so). If the scanner does not beep

once and the red light does not flash, then the bar code has not been

successfully read.

Three Beeps – During Operation

When entering the configuration mode, the red LED flashes while the scanner

simultaneously beeps three times. The red LED continues to flash until the unit

exits configuration mode. Upon exiting configuration mode, the scanner beeps

three times and the red LED stops flashing.

When configured for communication timeout, three beeps during operation

indicates that a communication timeout has occurred.