8

Symptoms

Possible Causes

Solution

The unit powers

up, but does not

scan and/or

beep.

The unit is trying to

scan a particular

symbology that is not

enabled.

UPC/EAN, Code 39, interleaved 2

of 5, Code 93, Code 128 and

Codabar are enabled by default.

Verify the type of bar code being

read has been selected.

The unit powers

up, but does not

scan and/or

beep.

The bar code being

scanned does not

satisfy the configured

criteria for character

length lock or

minimum length.

Verify the bar code being scanned

falls into the configured criteria.

The scanner defaults to a

minimum of three-character bar

code.

Serial Emulation USB Interfaces
The unit scans a

bar code, but

locks up after the

first scan and the

red LED stays

on.

The unit is configured

to support some form

of host handshaking

but is not receiving

the signal.

If the unit is setup to support

ACK/NAK, RTS/CTS, XON/XOFF

or D/E, verify that the host cable

and host are supporting the

handshaking properly.

The unit scans,

but the data

transmitted to the

host is incorrect.

The unit’s data format

does not match the

host system’s

requirements.

Verify the unit’s data format

matches that required by the host.

Make sure that the unit is

connected to the proper host port.

The unit beeps

at some bar

codes but NOT

for others of the

same bar code

symbology.

The bar code may

have been printed

incorrectly.

Check if it is a check

digit/character/or border problem.

The unit is not

configured correctly

for the type of bar

code being scanned.

The minimum symbol

length setting does

not work with the bar

code.

Check if the correct minimum

symbol length is set.

Keyboard Wedge Interface
The unit scans

the bar code but

there is no data.

The unit’s

configuration is not

correct.

Make sure the scanner is

configured for the appropriate

mode.