beautypg.com

10 replacement of parts – Glow-worm Micron 40FF User Manual

Page 27

background image

27

221911E

10 Replacement of Parts

Diagram 10.6

CLEAR
AIR TUBE

SECURING
SCREW (2)

AIR

PRESSURE

SWITCH

ELECTRICAL
CONNECTIONS

7227

Diagram 10.7

SECURING

SCREW

FAN

ASSEMBLY

ELECTRICAL

CONNECTIONS

FAN

SECURING

SCREW (3)

7165

CLEAR

AIR TUBE

10.11 Air Pressure Switch, Part No. 227032
- diagram 10.6

Gain Access as Section 5.2.

Remove the air pressure tube and electrical connections from
the switch, release the screws and remove the switch.

When fitting the replacement make sure that the plastic tube is
fitted as shown in diagram 10.6 and the electrical connections
are as shown in diagram 9.4.

10.12 Fan, Part No. 227033 - diagram 10.7

Refer to Section 5.3.

If top outlet installation: Remove air deflector, or it may just be
swung back by loosening the securing screws, to enable fan
assembly to be removed, see diagram 8.7 and Section 5.3.

Remove the electrical connections and disconnect the air tube.

NOTE: Remove the electrical connections by pulling insulation
boots only.

Remove the fan assembly securing screw at the front, then
withdraw the assembly.

The fan is secured to the flue hood by three screws.

The polarity of the electrical connections is not important.

IMPORTANT:
REMOVE ELECTRICAL CONNECTIONS
BY GRIPPING THE BOOT ONLY